FTS 812(L) USER MANUAL
Flash Technology, LLC
Revision 1 – 2/10/2022
11
2.4
INSTALL THE CO-MOUNT AND REMOTE-MOUNT UNITS
Install the co-mount and remote mount units on separate concrete pads as illustrated in Figure 2.2. Cut EMT pipe
such that the dimensions shown in Figure 2.2 are maintained. A bulls-eye level is supplied to assist in leveling the
units and is placed in a hole in the mounting brackets. Using this level as a guide, loosen the supplied 2” EMT
fittings at the top of the EMT conduit enough to allow the mounting bracket to be moved until it is level, then
tighten the fittings. Ensure that the mounting brackets are level after all fittings have been tightened.
Figure 2.2 – System Dimensions and Mounting Details
CONCRETE PAD
(SUPPLIED BY CUSTOMER)
FRANGIBLE FITTING (SUPPLIED)
(WITH 2” MALE NPT)
2” EMT FITTING (SUPPLIED)
2” EMT PIPE
(SUPPLIED BY CUSTOMER)
2” FEMALE NPT FLANGE FITTING
(SUPPLIED BY CUSTOMER)
LOOSEN THESE
FITTINGS TO
LEVEL FLASH HEAD