Thank you for purchasing LED Moving Head 120W SPOT MK2. For safety reasons and to ensure the trouble-
free operation, carefully read the instructions. 

2

 

SAFETY INFORMATION 

2.1

 

General information 

1.

 

Installation should be done by qualified personnel in order to minimize the risk of accidental 
electric shock. 

2.

 

Disconnect the power supply before installation. 

3.

 

Before connecting the unit to the mains, make sure it is not damaged mechanically. If you 
notice any signs of damage you should contact your dealer immediately. Do not connect the 
device to the mains. 

4.

 

Do not use the device in high humidity conditions and at temperatures above 40° C 

5.

 

The device must be installed on stable structures. 

6.

 

Please keep this user guide for future consultation. If you sell the unit to another user, be 
sure that they also receive this instruction booklet. 

7.

 

Always make sure that you are connecting to the proper voltage, and that the line voltage 
you are connecting to is not higher than that stated on the decal or rear panel of the fixture. 

8.

 

This product is intended for indoor use only! 

9.

 

To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure that 
there are no flammable materials close to the unit while operating. 

10.

 

The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from 
adjacent surfaces. Be sure that no ventilation slots are blocked. 

11.

 

Always  disconnect  from  power  source  before  servicing  or  replacing  fuse  and  be  sure  to 
replace with same fuse size and type. 

12.

 

Secure fixture to fastening device using a safety chain. 

13.

 

Never carry the fixture solely by its head. Use its carrying handles. 

14.

 

In case of a serious operating problem, stop using the unit immediately. Never try to repair 
the unit by yourself. 

15.

 

Repairs carried out by unskilled people can lead to damage or malfunction. Please contact 
the nearest authorized technical assistance center. Always use the same type spare parts. 

16.

 

Don't connect the device to a dimmer pack. 

17.

 

Make sure the power cord never crimped or damaged. 

18.

 

Never disconnect the power cord by pulling or gagging on the cord. 

19.

 

Avoid direct eye exposure to the light source while it is on. 

 

2.2

 

AC Power 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of the 
fixture or referred to the fixtures specification chart. A fixture listed current rating is its average current draw 
under normal conditions. All fixtures must be directly powered off switched circuit and cannot be run off a 
rheostat  (variable  resist)  or  dimmer  circuit,  even  if  the  rheostat  or  dimmer  source  voltage  matches  the 
fixtures requirement. Check the fixture or device carefully to make sure that if a voltage selection switch 
exits that it is set to the correct line voltage you will use. 

Summary of Contents for F7100079

Page 1: ...USER MANUAL INSTRUKCJA OBS UGI LED Moving Head 120W SPOT MK2 F7100079...

Page 2: ...Master Slave fixture linking 5 5 4 Voltage specification 5 5 5 Connecting power supply 5 6 Menu 6 7 DMX channel list 7 Spis Tre ci 1 Wprowadzenie 8 2 Bezpiecze stwo 8 2 1 Informacje o bezpiecze stwie...

Page 3: ...ith adequate ventilation at least 20in 50cm from adjacent surfaces Be sure that no ventilation slots are blocked 11 Always disconnect from power source before servicing or replacing fuse and be sure t...

Page 4: ...lay LCD Matrix Color Color wheel 7 colors white Beam angle min 15 Beam angle max 15 Dimming Linear 0 100 Prism 3 facet prism FOCUS Electronic GOBO wheel 7 patterns open PAN range 630 Number of DMX cha...

Page 5: ...high quality signal and are less prone to electromagnetic interference Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristic...

Page 6: ...female 3pin connector to the input connector of the next fixture consisting of a male 3pin connector Then proceed to connect from the output to the input of the following fixture and so on 5 4 Voltage...

Page 7: ...Program Alone Master Music Control Alone Master Slave Control Reset ON OFF Pan Reverse ON OFF TiltReverse ON OFF Mic Sensitivity 0 100 Special Reset Default ON OFF Calibration Code Temperature Show te...

Page 8: ...n slow fast CH 7 Gobo rotation 0 10 No function 11 130 Clockwise rotation fast slow 131 135 Rotation stop 136 255 Counterclockwise rotation slow fast CH 8 Shutter 0 9 Closed 10 245 Strobe slow fast 24...

Page 9: ...panelu urz dzenia 8 Ten produkt jest przeznaczony do u ytku w pomieszczeniach zamkni tych 9 Aby unikn ryzyka po aru lub pora enia pr dem nie wystawia urz dzenia na dzia anie deszczu lub wilgoci Upewni...

Page 10: ...wid owe napi cie Je li ustawione napi cie nie jest zgodne z napi ciem sieci urz dzenie mo e zosta uszkodzone Urz dzenie musi by pod czone do obwodu z odpowiednim uziemieniem 3 SPECYFIKACJA Pob r mocy...

Page 11: ...3 pin 2 Zasilanie wej cie wyj cie z cza powerCON 5 1 Pod czanie sygna u DMX Po czenie odbywa si przy u yciu przewodu z wtyczkami XLR e ski XLR M ski Aby po czy oprawy razem nale y zastosowa odpowiedni...

Page 12: ...1 Pod cz z cze XLR 3 pin m skie do wyj cia DMX e skiego z cza XLR 3 pin pierwszego urz dzenia 2 Pod cz drugi koniec kabla pod czonego wcze niej do pierwszego urz dzenia do wej cia DMX nast pnego urz...

Page 13: ...Alone Master Music Control Alone Master Slave Control Reset ON OFF Pan Reverse ON OFF TiltReverse ON OFF Mic Sensitivity 0 100 Special Reset Default ON OFF Calibration Code Temperature Temperatura urz...

Page 14: ...t w lewo wolno szybko CH 7 Gobo obr t 0 10 Brak funkcji 11 130 Obr t w prawo szybko wolno 131 135 STOP 136 255 Obr t w lewo wolno szybko CH 8 Przyslona strobo 0 9 Zamkni ta 10 245 Strobo wolno szybko...

Reviews: