www.flash-butrym.pl
Strona 29
21
Blue (3,7,11,15)
22
Red (4,8,12,16)
23
Green (4,8,12,16)
24
Blue (4,8,12,16)
Note: *When the channel is opening, please confirm the
channel 1
st
is phase-in.
3. Setup
3.1 F ixtu re l in kin g
When you control the light
’s master/slave or DMX 512 signal
agreement, the lights can be connected by signal wire which the
distance is
≤
500m,The maximum connect lights are 32pcs more or
less, and adapt DMX light pair to segregate the signal zoom
equipment, in order to protect the light
’s signal won’t be interrupted
by other signal. Moreover, it won
’t affect by the signal wire’s length
D ata co n n ect
Data cable is connected by DMX data wire, and XLR. Please use hi-
quality data cable signal wire, it won
’t be interrupted by magnetic.
C h aracteris tics o f D MX d ata cab le
2
conductors’ double tree lace and shield.
The maximum capacitance of the conductors-30 pF/ft.
The maximum capacitance of the conductor and shield -55 pF/ft.
The maximum resistance is 20 ohms/1000ft.
The nominal impedance 100-140 ohms.
DMX opt coupler segregate signal zoom equipment
’s 3 pin(5 pin)
XLR plug.
3.2 Setting up a DMX signal connect
As following pictures show, please connect the first light to the signal
cable which is with XLR by DMX controller, then, connect light in
series.