Parts & Their Functions
Bright/F.D./Ref Pos.
: Used to adjust brightness higher or lower. Pressing down on the center of this button will
return the brightness setting to its default position. The brightness knob should NOT be used increase the overall
peak white luminance of the unit, use the BACKLIGHT setting on the video menu to adjust overall luminance.
Chroma / V Pos
: Used to adjust chroma higher or lower. Pressing down on the center of this button will return
the chroma setting to its default position.
Phase / H Pos
: Used to adjust phase. Pressing down on the center of this button will return the setting to default.
Hue is locked by default on SDI, but can be unlocked from the SDI Hue Adjustment option on the System Menu.
Tally
: Three color tally lamp controlled via remote control.
Rear
LAN
: Inactive—Factory Use Only.
GPI
: General Purpose Interface for Contact Closure Remote Control.
Remote Control Functions can be assigned from Monitor Main Menu.
RS-485
: RS-485 Ports (In/Out) for looping remote control interface.
DVI-I
: DVI-I Input. Supports both DVI-Analog & DVI-Digital. Analog/
Digital Toggle is found on System Menu.
Video In/Out
: Composite Video Input & Loop Through.
Component In/Out
: Component Video (SD & HD autosensing) Input &
Loop Through. Supports both YPbPr & RGB signals.
Ext. Sync. In/Out
: External Reference Synchronization Interface.
SDI In 1 & SDI In 2
: Two Autosensing, Autoswitching, Multi-Format HD/SD-
SDI Inputs. Both Inputs support SD or HD SDI Signals, & 3Gbps if installed
SDI Out 1 & Out 2
: Two mirrored SD/HD-SDI Outputs (& 3Gbps if in-
stalled). Please note that both Outputs pass through the identical active
SDI channel, not two distinct channels.
Audio In/Out
: Analog Stereo Mini-phono Audio Input & Output.
AC
Power
DC
Power
6