Flamerite Fires Corello Installation Precautions Download Page 2

 

 

Using as a Hole in the Wall:  

THE SPACER MUST BE REMOVED (FIG.2) 

 

Fig.1                             

          

 

 

 

Fig.2 

 

Removing the decorative front (Fig.1), there are two screws either side of the heater outlet next to the on/off switch and the keypad and two 

inside the fire under the fuel bed area beneath the lamps (B).   To remove the spacer there are eight screws (A) on the rear of the case (Fig.2).   

Four keyhole slots should now be visible, two on each side of the outer return.  Place the fire into the hole, mark off at the TOP of the keyhole 

slots where the fixing holes are to be drilled.  Remove fire and drill the holes.  When this is done push the rawl plugs into the drilled holes and 

half screw in the fixings.  Finally lift and hook the fire back onto the fixings and tighten.  The decorative front may be reapplied. 

 

Using as a Hang on the Wall.  The rail should be fixed to the wall with the hook facing upward and outward.  Once the rail has been fixed in 

place, lift and hook the fire onto the rail.  Next at the back of the case bottom/centre is a fold out tag.  Fold this down as to expose it under the 

fire when it is hung in place.  Mark off through the hole, remove fire, drill and fit rawl plug.  Hang the fire back on the wall and secure in place 

using the screw provide. 

 

Fuel effect Pebbles/coal 

Once the fire has been installed in the correct position unpack the pebbles/coals from the accessory box and arrange on the fuel bed.   

 

MAINTENANCE 

 

Before any maintenance/cleaning is undertaken, always disconnect the fire from the mains power supply. 

 

Replacing Lamps (Dimmable 240V 7W 3000k E14 LED lamps): Replacements are available from Flamerite Fire

[email protected]

   

Allow a suitable time for the lamps to cool then remove the glass & fuel effect (see Installation).  Remove the two screws from either side of 

the fuel bed and lift out of place.  Remove and replace the lamps, fuel bed, fuel effect and glass.  Please note that replacement Lamps are only 

covered from purchase by a 2 year warranty 
Cleaning 

The fire can be cleaned with a soft damp cloth and none abrasive glass cleaner.  

 

WARNINGS 

 

Do not open and close the glass repeatedly while the heater is on or the cut out will activate. 

 

Do not use the fire in the vicinity of a bath shower or swimming pool. 

 

Never use the fire to dry laundry. 

 

Never install the fire directly underneath a fixed main socket. 

 

Never cover the appliance during the operation of the fire. 

 

The use of an extension lead is not recommended. 

 

Particular caution should be applied to ensure that children do not play with the fuel effects. 

 

As with any electrical appliance whilst the instructions aim to cover as many eventualities as possible, caution and common sense 

should be applied when operating your appliance, particularly in the vicinity of small children. 

 

Areas around the fire will become hot when activated.  We strongly recommend small children be kept away from having any direct 

contact with the appliance by means of fitting a fireguard.  This appliance is not intended for use by persons (or children) with 

reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or 

instruction concerning the use of the appliance by the person responsible for their safety.   Children should be supervised to ensure 

they do not play with this appliance. 

 