Your fire has been designed for use as part of a fireplace mantel and surround suite. A minimum depth of up to 75mm may be required. The
dimensions of the aperture in the decorative back panel into which the fire fits are, height maximum 595mm and minimum 560mm and width
maximum 440mm and minimum 405mm. The fire must be positioned so that the plug socket is accessible once the fire has been installed. In the
unlikely event of breakdown access must be allowed to the rear so that the fire maybe serviced, do not seal to the wall. The mains cable must
therefore be long enough to allow this. If the removal of the plug is absolutely necessary for installation, cut off in an area within 100mm only of
the plug itself. Any further may affect your warranty. Where the inset fire is being used in an existing chimney, it is important that the chimney is
blocked off to prevent airflow problems with the fire. Where a chimney is not blocked off sufficiently, it may cause the heater to cut out and the
flame effect to stop or work inefficiently.
Electrical connections
Your appliance comes fitted with a plug that incorporates a 13A fuse. The replacement fuses must be 13A and ASTA approved. If the fuse cover is
lost the plug must not be used until a replacement cover, of the same colour, is obtained from an electrical retailer.
The appliance is fitted with a moulded plug if it is necessary cut off the plug, for any reason, it must be discarded immediately with the fuse
removed. Under no circumstances should any attempt be made to reuse the plug, do not insert into any 13A socket as this could cause a
hazard. If the mains cable is damaged it must be replaced by the manufacturer or an authorised technical service centre.
WARNING THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with the following code.
Green and yellow:
EARTH
Blue:
NEUTRAL
Red:
LIVE
As the colours of the wires in the mains lead of this appliance may not correspond with the colour markings in your plug proceed as follows: -
The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E, or
coloured green or coloured green and yellow, or marked with the earth symbol
The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N, or coloured
black.
The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter L, or coloured
red.
Fret and fuel effect.
Once the fire has been installed in the correct position, should it be required place the fret in front of the fire. For the Cisko, place the
frame onto the fire and over the fret clamping the rear most sides of the fret tightly in between the frame and the case. Unpack the fuel
effect from the accessory box and arrange in a random formation on top of the orange fuel bed.
Operating the fire
Manual Control Fire Only
The on/off switch is located under the hood; this is marked with I/O and will need to be pushed to illuminate the
flame effect.
For heating the controls are located under the hood of the fire also next to the on/off switch. For 1kw of heat push
the switch marked with a single bar
I
. For 2kw of heat push the switch marked with the double bars II. Both
switches have to be depressed for 2kw of heat. The flame effect has to be illuminated for the heater to work.
Remote Control Fire Only
The fire may only be operated by the remote control. The on/off switch is located under the hood; this is marked with I/O
and will need to be pushed to I to operate the remote. If an Extreme, the back light behind the fret will come on.
To turn the fire on, simply press and release the FIRE ON
button on the remote keypad.
To set the light to your desired brightness, press then release the button marked DIMMER
. You will notice
the flame effect brightness will continuously phase from high to low. At the desired point press then release the
DIMMER
button to stop the phasing.