10
3.6 SYSEX Data format
The assignment of the MIDI data for the voices (and thus the multimodes 1-5) and for the two
controller outputs (modulation and pitch bend) can be done with the help of SYSEX data. The
module understands different types of SYSEX files:
Typ 1:
SYX file for all data
Typ 2:
SYX file for setting the control change number and the
midi channel from CV output modulation
11110000
F0
Exclusive Status
01111101
7D
Header Flame module
00001011
0C
Flame module “µQMCV”
00000001
01
version 1
00000110
06
data type 1 (dump all data)
0000xxxx
nch1
4 data bytes MIDI channels for voices 1-4
|
|
(range: 00=channel 1 .. 0F=channel 16)
0000xxxx
nch4
0xxxxxxx
ccnr
1 data byte control change number of Modulation output
(range: 00=CCnr 0 .. 7F=CCnr 127)
0000xxxx
ccch
1 data byte MIDI channel of Modulation output
0000xxxx
pbch
1 data byte MIDI channel of Pitchbend output
(range: 00=channel 1 .. 0F=channel 16)
11110111
F7
End of Exclusive
(total 13 bytes)
11110000
F0
Exclusive Status
01111101
7D
Header
00001011
0C
Flame module “µQMCV”
00000001
01
version 1
00000111
07
data type 2 (dump data Modulation output)
0xxxxxxx
ccnr
1 data byte control change number of Modulation output
(range: 00=CCnr 0 .. 7F=CCnr 127)
0000xxxx
ccch
1 data byte MIDI channel of Modulation output
(range: 00=channel 1 .. 0F=channel 16)
11110111
F7
End of Exclusive
(total 8 bytes)