Frequency converter Fc102 (quick guide)

control unit (lcp)

a. alphanumeric display

The information displayed in the control unit display (LCP) can 
be customised. See parameters 0–20, 0–21, 0–22, 0–23 and 
0–24. The factory settings display: motor rpm, motor current, 
motor output, motor frequency and reference.

B. menu buttons

Use the menu buttons to access the parameter settings, to 
toggle between status display modes during normal operation 
and to display fault log data.

c. navigation and indication

[Back] returns to the previous step or menu list [Cancel] 
Cancel the latest change or command [Info] Provides informa-
tion of the function displayed [

] [

] [

] [

] navigate and 

increase/decrease [OK] Activate selection or access a 
parameter group 

•  Green indication – power on
•  Yellow indication – warning
•  Red indication – alarm

d. driftslägesknappar och återställning

[Hand/on] – Starting the motor for local control
[Off] – Stopping the motor
[Auto/on] – Allow control via control terminals or the commu-
nication bus
[Reset] – Resetting alarms

manual operation

•  Press [Hand/on] to start
•  Press the navigation buttons to set the desired speed
•  Press [Off] to stop
•  Press [Auto/on] to return to automatic operation

reverse the direction oF rotation

If necessary the direction of rotation can be reversed using 

parameter 1–06. When connection is correct 0=clockwise and 

1=anti-clockwise.

more inFormation

This quick guide contains the basic information needed to 

install and operate the frequency converter.
There is more information available in the attached docu- 

mentation.

Auto

on

Reset

Hand

on

Off

Status

Quick

Menu

Main

Menu

Alarm

Log

Canc

el

Inf

o

Status

1(1)

1234rpm

Back

OK

43,5Hz

Run OK

43,5Hz

On

Alarm

Warn.

130BC362.10

a

b

c

d

1.0 A

a

b

c

d

Summary of Contents for FC102

Page 1: ...onnections 3 Control unit LCP 4 Manual operation 4 Reverse the direction of rotation 4 More information 4 Wiring diagram 5 Basic configuration 6 PID regulation 7 AIRTREATMENT 9325GB2016 09 16 AIRCOMFO...

Page 2: ...mains voltage disconnecting permanent magnet motors and DC bus supplies including battery backup UPS and DC bus connections for other frequency converters Wait until the capacitors have fully dischar...

Page 3: ...alogue I O 4 LCP contact 5 Analogue switches 6 Cable support PE earth 7 Earthing plate 8 Earth clamp 9 Shielded cable earth clamp and cable support 10 Motor connection 11 Relay 1 12 Relay 2 13 Brake a...

Page 4: ...ion or access a parameter group Green indication power on Yellow indication warning Red indication alarm D Driftsl gesknappar och terst llning Hand on Starting the motor for local control Off Stopping...

Page 5: ...5 40 0 Relay output 1 Run Indicator NO NC Param 5 40 1 Start Reference 0 10VDC FW standard Actual value PID regulation Start Danfoss FC102 24V 12 24V 13 DIG IN 18 DIG IN 19 COM 20 DIG IN 27 DIG IN 29...

Page 6: ...z 12 Apply on terminal block 53 Yes Yes 13 Application Fan Fan 14 Autom Energy Optimisation Yes 2 4 pon Yes 2 4 pin No other No other 15 AMA Yes Yes 16 Con rm AMA OK OK 17 Press Main Menu twice 18 Sel...

Page 7: ...20 14 Maximum Reference Feedb ______________Pa ______________Pa 9 Press once 10 6 24 Terminal 54 Low Ref Feedb 0 Pa 0 Pa 11 6 25 Terminal 54 High Ref Feedb ______________Pa ______________Pa 13 6 26 Te...

Page 8: ...p bits 2 No parity 1 Stop bit Parameter Description TF FF 6 50 Function terminal block 42 4 20mA 4 20mA Parameter Description TF FF 6 14 Output frequency equivalent to 4mA 0 Hz 0 Hz 6 15 Output freque...

Reviews: