Flair Smart Vent Installation Manual Download Page 3

 
 
 

5.  Attach Faceplate 

Attach the faceplate with the two screws and 
you are all finished.  Install any other vents and 
move over to the digital setup via the Flair App 
or 

my.flair.co

 

6.  Digital Installation 

For initial setup of your Flair System, be sure to 
refer to the Puck Installation Guide.  Once you 
are ready to associate the vent with a room, the 
light bar should show a unique code.  

If you don’t see any lights on your vent’s light bar or if you are 

adding this vent to an already configured system

, go to 

Home Settings → Flair Devices

 and enable 

Setup Mode

 

Wired Installation 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

24VAC Optional Power Port 

Use with: 20AWG Plenum Rated Solid 2 Conductor Wire 

@24VAC: less than 1mA continuous, max 50mA Intermittent 

 
 
 
 

Summary of Contents for Smart Vent

Page 1: ...the following support flair co 1 800 590 6943 Monday Friday 9am to 5pm PST What s in the Box A Smart Vent C 2 C Cell Batteries E Top Battery Holder B 2 Mounting Screws D Bottom Battery Holder F Battery Holder Screws Assembly and Installation 1 Attach Bottom Battery Holder Insert the Bottom Battery Holder into the back of the vent Screw in the two Battery Holder Screws Ensure the screws are fully i...

Page 2: ...the vent into the wall or ceiling Using the supplied mounting screws insert the screws into the mounting holes on the two ends of the vent Closest to the middle of the vent is the best location in the slot but you may need to insert the screws farther from the center of the vent to align with existing holes In most cases your existing holes should work great If however the mounting holes are strip...

Page 3: ...refer to the Puck Installation Guide Once you are ready to associate the vent with a room the light bar should show a unique code If you don t see any lights on your vent s light bar or if you are adding this vent to an already configured system go to Home Settings Flair Devices and enable Setup Mode Wired Installation 24VAC Optional Power Port Use with 20AWG Plenum Rated Solid 2 Conductor Wire 24...

Page 4: ...s not matter 7 If there is excessive wire in the boot or duct trim the wire repeat step 5 Ensure that the wire doesn t interfere with the Vent s louvre movement Also ensure the two wires are fully separated and cannot short near the vent terminal block In case of excess exposed wire at the vent terminal block press the release buttons on the terminal block and pull the wires out Trim exposed wire ...