background image

 

Smart Vent Installation Guide 
 
 

Welcome to the Flair community! 

 

Our users are energy nerds, home automation gurus, and HVAC Pros.  If you have any questions, feel free to 
check out the forums at 

forum.flair.co

 
If you don’t see what you are looking for there, you can reach us at one of the following: 
 
[email protected] 
+1 (800) 590 6943 
Monday-Friday, 9am to 5pm PST 
 

 

What’s in the Box? 

 
 
 
 
 
 
 
 
 
 
 

A. Smart Vent 

C. 2 C Cell Batteries 

E. Top Battery Holder 

B. 2 Mounting Screws 

D. Bottom Battery Holder 

F. Battery Holder Screws 

 

 

Assembly and Installation

 

 

 
1. Attach Bottom Battery Holder 

Insert the Bottom Battery Holder into the back of 
the vent.  Screw in the two Battery Holder 
Screws.  Ensure the screws are fully inserted 
and snug but 

do not over tighten

 as you might 

strip the plastic. 
 

Over → 

Summary of Contents for Smart Vent

Page 1: ...the following support flair co 1 800 590 6943 Monday Friday 9am to 5pm PST What s in the Box A Smart Vent C 2 C Cell Batteries E Top Battery Holder B 2 Mounting Screws D Bottom Battery Holder F Battery Holder Screws Assembly and Installation 1 Attach Bottom Battery Holder Insert the Bottom Battery Holder into the back of the vent Screw in the two Battery Holder Screws Ensure the screws are fully i...

Page 2: ...the vent into the wall or ceiling Using the supplied mounting screws insert the screws into the mounting holes on the two ends of the vent Closest to the middle of the vent is the best location in the slot but you may need to insert the screws farther from the center of the vent to align with existing holes In most cases your existing holes should work great If however the mounting holes are strip...

Page 3: ...refer to the Puck Installation Guide Once you are ready to associate the vent with a room the light bar should show a unique code If you don t see any lights on your vent s light bar or if you are adding this vent to an already configured system go to Home Settings Flair Devices and enable Setup Mode Wired Installation 24VAC Optional Power Port Use with 20AWG Plenum Rated Solid 2 Conductor Wire 24...

Page 4: ...s not matter 7 If there is excessive wire in the boot or duct trim the wire repeat step 5 Ensure that the wire doesn t interfere with the Vent s louvre movement Also ensure the two wires are fully separated and cannot short near the vent terminal block In case of excess exposed wire at the vent terminal block press the release buttons on the terminal block and pull the wires out Trim exposed wire ...

Reviews: