PRESSURES:  

MAXIMUM INLET PRESSURES:   

LP: 14.0 IN. WC. 
NG: 14.0 IN. WC. 

 

MINIMUM INLET PRESSURES:    

LP: 11.0 IN. WC. 

NG: 3.5 IN. WC. 

 

This heater must be supplied by pressures indicated on the 
approval label. Over pressure may cause controls to fail. 

 

DO NOT supply this unit with more than ½ psig (14.0 in. W.C.) 
Note: A second stage regulator must be installed if the supply 
pressure exceeds ½ psig. 

 
FUEL:  

 

This heater will operate on propane or natural gas. The manifold 
pressures are listed on the approval label. Ensure that the proper 
pressure settings are achieved depending on the fuel being used. 

 

A fuel selector valve is located on the manifold of the heater. 
Ensure that this valve is in the proper position depending on the 
fuel being used. DO NOT operate the heater with the valve in the 
incorrect position. 

 
HOSES:  

 

All hoses used to connect this heater of fuel supply must be Type 1 
approved propane / natural gas hose assemblies. 

 
 
 
 
 
 
 
ELECTRICAL:  

 

 

 

WARNING 

Electrical Grounding Instructions 
 

This appliance is equipped with a three-prong (grounding) plug for 
your protection against shock hazard and should be plugged 
directly into a properly grounded three-prong receptacle. 

 

120v supply must be available. Please note that the motor on this 
unit requires 15 amps. Ensure appropriate gauge extension cord is 
used. 

 
 
 
 
 

Summary of Contents for F-400T

Page 1: ...ture reference For F 400T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U S A As per Standard ANSI Z83 7 2000 CSA 2 14 2000 Gas Fired Construction Heaters Unvented Unattended Type FLAG...

Page 2: ...SION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY...

Page 3: ...YOU HAVE QUESTIONS ABOUT APPLICATIONS Other standards govern the use of fuel gases and heat producing products in specific applications Your local authority can advise you about these SPECIFICATIONS...

Page 4: ...apor withdrawal only 1 All cylinder connections must be made using a wrench to tighten the POL fitting 2 Be sure that the cylinder valve is in the closed position when connection or disconnecting the...

Page 5: ...depending on the fuel being used A fuel selector valve is located on the manifold of the heater Ensure that this valve is in the proper position depending on the fuel being used DO NOT operate the he...

Page 6: ...into operation The replacement hose assembly shall be that specified by the manufacturer 3 The appliance must be kept clear and free from combustible materials gasoline and other flammable vapors and...

Page 7: ...4 Open all gas supply valves 5 Depress the main switch to the START position The fan will start and the burner should ignite 6 Set the Thermostat to the desired temperature 7 If heater fails to ignit...

Page 8: ...urn counter clockwise to decrease sensitivity POSSIBLE CAUSE Blockage in copper inlet tubes REMEDY Disconnect tubes from air switch Use high pressure air to clean any debris that my block the airflow...

Page 9: ...sures are supplied to the heater see approval label POSSIBLE CAUSE Spark Plug REMEDY Ensure gap in spark plug is approx 3 16 Check spark plug wire connections Ensure spark plug has good spark Replace...

Page 10: ...rd POSSIBLE CAUSE Thermostat REMEDY Ensure the thermostat is calling for heat POSSIBLE CAUSE Electrical All components REMEDY Before replacing an component all connections must be checked to ensure el...

Page 11: ...UEL SELECTOR VALVE S 403 IGNITOR S 408A FAN BLADE S 401 PRESSURE ADJUSTMENT CAP FOR S 402 REG S 402C REGULATOR 1 2 PSI S 402 S S FILTER SCREEN S 402FS SOLENOID VALVE COVER 200871 002 FLAME ROD S 406A...

Page 12: ...HARNESS S 415W IGNITION BOARD S 415P MAIN RELAY S 412 AIR PROVEN SWITCH S 414 THERMOSTAT S 416 FRONT LEG S 418 REAR SCREEN S 419 6 RUBBER WHEELS S 420 PIPE CLAMP S 423 AIR SENSING TUBES S 427 POWER CO...

Page 13: ...IT S 411 OFF RUN START SWITCH S 412 MAIN RELAY S 414 AIR PROVING SWITCH S 415P POTTED IGNITION CONTROL 120V 2002 TO CURRENT S 416 THERMOSTAT WK 400 WHEEL KIT S 418 FRONT LEGS S 419 SCREEN S 420 RUBBER...

Page 14: ...FLAME ROD SPARK PLUG FENWAL IGNITION BOARD GROUND F 400T WIRING DIAGRAM 2010 400T 202 F 400T WIRING DIAGRAM 2010 Note If any of the origional wire as supplied with the appliance must be replaced it mu...