12
the tank runs out of water or if the unit runs in dry operation.
- To restart the humidifier, disconnect the plug and wait 5 minutes for it to
cool down. Top up with water and restart from (point 4).
MAINTENANCE AND CLEANING
Always disconnect the power cable (2.1) and wait 30 minutes for the device to cool
down, before cleaning. For ex-tended periods of non-use, store the device, only
when it is clean and dry, inside its box.
ATTENTION: Presence of excessive scale may be found on the resistance due
to lack of or poor maintenance and cleaning operations. This may be the cause
of malfunctions on the ON/OFF night light (2.7) even when the tank is full.
Daily cleaning/maintenance:
1- Remove the heating unit (2) by rotating it and pulling it upwards (Fig. B).
2- Fully drain the tank. Ensure that water drains from the hole (1.3) (Fig. G).
3- Before refilling the tank, clean and rinse a couple of times with abundant water. If
you do not use it immediately, drain and dry with a cloth.
Warning:
DO NOT use abrasive detergents or brushes. DO NOT leave water in the
water tank when the device is not running. This prevents bacteria from forming in
the tank.
Weekly cleaning/ maintenance:
1- On a weekly basis, clean the humidifier as described in “Daily cleaning”.
2- Clean the heating unit. Immerse the heating unit into 10 cm of solution containing
50% water and 50% white vinegar for 10 minutes. Lastly, rinse abundantly with
hot water (approximately 40 °C) see (Fig. H).
End of season cleaning/maintenance:
1- Clean the humidifier as described in “Weekly cleaning”.
2- Descale the resistance (2.6), by removing the cap of the heating unit (2.5) rotating
it anti-clockwise (fig. I). Use a regular sponge to remove the scale (fig. L).
Summary of Contents for P0413ED
Page 1: ...1...
Page 40: ...39 www flaemnuova it 1 2 1 1 1 1 2 IN OUT 1 3 2 2 1 2 2 2 3 2 4 2 5 2 6 2 7 FLAEM...
Page 41: ...40 8 2...
Page 42: ...41 1 2 1 2 2 1 2 3 1 3 1 1 1 4 5 4 2 1 b...
Page 43: ...42 2 4 1 2 5 1 2 2 E 2 2 6 2 7 7 2 3 F 8 2 7 10 1 5 4 2 1 30 2 7 1 2 B 2 1 3 G 3...
Page 44: ...43 1 2 10 50 50 10 40 C H 1 2 2 6 2 5 I L...
Page 45: ...44 2 7 5 1 1...
Page 46: ...45 2006 95 P0413ED 25 m2 220 240V 50Hz 240 260W 10 to 40 C 50 F 104 F 27 29 22 1 3 4 5 14...
Page 47: ...46 www flaemnuova it Flaem 1 2 1 1 1 2 1 3 1 FLAEM 8 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2...
Page 48: ...47 2...
Page 50: ...49 30 1 2 7 2 2 1 3 1 2 3 1 10 50 50 10 2 40 1 5 2 6 2 2 7 2 5 1 1...
Page 51: ...50 2006 95 EC P0413ED 2 25 240 260 50 220 240 104 50 40 10 x 22 x 29 27 1 3 4 5 14...
Page 66: ...65 59 2 DC a b...
Page 68: ...67 61 2 1 30 2 7 1 2 B 2 1 3 G 3 1 2 10 50 50 10 40 H 1 2 I 2 5 2 6 L ON OFF 2 7 5 1 1...
Page 69: ...68 62 2006 95EC P0413ED 25 220 240V 50Hz 240 260W 10 40 50 104 cm 27 x29 x22 1 3Kg 4 5 14...