Digital Thermometer
MT3001
Description of this Thermometer
ON/OFF button
Display
Battery compartment cover
Measuring sensor
Important Safety Instructions
• The instrument may be used only for measuring body temperature!
• The minimum measurement time until the beep is heard must be maintained without exception!
• Ensure that children and disabled persons do not use the instrument unsupervised; some parts are
small enough to be swallowed.
• Protect the instrument from impact and dropping!
• Avoid ambient temperatures above 60 °C. NEVER boil the instrument!
• Use only the commercial disinfectants listed in the section «Cleaning and Disinfecting» to clean the
instrument.
Batteries and electronic devices must be disposed of in accordance with the locally applica-
ble regulations, not with domestic waste. Illegal dumping of the product by the user entails the
administrative sanctions stated in article 50 et seq of Legislative Decree n. 22/1997.
Important: check the operating instructions
Type BF applied part
Turning on the Thermometer
To turn on the thermometer, press the ON/OFF
button
a short beep signals «thermometer
ON». A display test is performed. All segments
should be displayed. Then at an ambient tem-
perature of less than 32 °C, an «L» and a flash-
ing «°C» appear at the display field . The ther-
mometer is now ready for use.
Function Test
Correct functioning of the thermometer is tested
automatically each time it is turned on. If a mal-
function is detected (measurement inaccuracy),
this is indicated by «ERR» on the display, and a
measurement becomes impossible. In this case,
the thermometer must be replaced.
Using the Thermometer
Choose the preferred measuring method. When
taking a measurement, the current temperature
is continuously displayed and the «°C» symbol
flashes. If the beep is heard 10 times and the
«°C» is no longer flashing, this means that the
measured increase in temperature is less than
0.1 °C in 16 seconds and that the thermometer
can now be read. To prolong the battery life, turn
off the thermometer by briefly pressing the ON/
OFF button
. Otherwise the thermometer will
automatically turn off after about 10 minutes.
Storage of Measured Values
If the ON/OFF button
is pressed for more than
3 seconds when turning on the thermometer, the
automatically stored maximum temperature dur-
ing the last measurement will be displayed. At the
same time, a «M» for memory will appear on the
display. About 2 seconds after the button is re-
leased, the temperature value disappears and the
thermometer is ready for measurement.
Measuring methods / Normal body tem-
perature
→
In the mouth (oral) / 35.5 - 37.5 °C
Position the thermometer in one of the two pock-
ets under the tongue, to the left or right of the root
of the tongue. The measuring sensor
must be
in good contact with the tissue. Close your mouth
and breathe evenly through the nose to prevent
the measurement from being influenced by in-
haled/ exhaled air.
Approx. measuring time: 1 minute!
→
In the anus (rectal) / 36.6 - 38.0 °C
Carefully insert the measuring sensor
of the
thermometer 2 to 3 cm into the anal aperture.
Approx. measuring time: 1 minute!
→
In the armpit (axillary) / 34.7 - 37.3 °C
A minimum measurement time of 3-5 minutes is
recommended regardless of the beep sound.
Approx. measuring time: 1 minute!
At home, for measurement by parents, for
all children measurement with electronic
thermometer in the armpit is recommended.
(Source: Italian Society of Pediatrics)
Cleaning and Disinfecting
Use an alcohol swab or cotton tissue moistened
with alcohol (70% Isopropyl) to clean the ther-
mometer. Please never immerse into liquids!
Battery Replacement
When the «
▼
» symbol (upside-down triangle) ap-
pears at the display field, the battery is flat and
needs replacing. To replace the battery remove
the battery compartment cover
from the ther-
mometer.
Insert the new battery with the
+
at the top. Make
sure you have a battery of the same type to hand.
Batteries can be purchased at any electrical
store.
Technical Specifications
Type:
Maximum thermometer
Measurement range:
32.0 °C to 43.9 °C
Temp. < 32.0 °C: display «L» for low (too low)
Temp. > 43.9 °C: display «H» for high (too high)
Measurement accuracy:
± 0.1 °C between 34 °C and 42 °C
Operating temperature:
10 - 40 °C; 15-95 % relative maximum humidity
Storage temperature:
-25 - +60 °C; 15-95 % relative maximum humidity
Battery:
1.5V; LR 41
Reference to standards:
EN 12470-3, clinical thermometers;
ASTM E1112; IEC 60601-1; IEC 60601-1-2 (EMC)
This device complies with the requirements of the Medical Device Directive 93/42/EEC.
Technical alterations reserved.
Specifiche tecniche
Tipo:
Termometro a misurazione massima
Range di misurazione:
Da 32.0 °C a 43.9 °C
Temp. inferiore a 32.0 °C: «
L» (troppo basso)
Temp. superiore a 43.9 °C: «
H» (troppo alto)
Precisione di misurazione:
± 0.1 °C tra i 34 °C e i 42 °C
Temperatura di esercizio:
10 - 40 °C; 15-95 % umidità relativa
Temperatura di stoccaggio: -25 - + 60 °C; 15-95 % umidità relativa
Batteria:
1.5V; LR 41
Riferimento agli standard:
EN 12470-3, termometri clinici;
ASTM E1112; IEC 60601-1; IEC 60601-1-2 (EMC)
Questo dispositivo è conforme alla direttiva sui prodotti medicali 93/ 42/EEC.
Con riserva di apportare modifiche tecniche.
Distribuito da / distribuited by:
FLAEM NUOVA S.p.A. - Via Colli Storici, 221
25015 S. Martino della Battaglia (BS) Italy
www.flaem.it
Microlife AG, Espenstrasse 139
9443 Widnau / Switzerland
Onbo Electronic (Shenzhen) Co.,Ltd
No. 497, Ta Laneg Nan Road,
Ta Laneg Street, Baoan District,
Shenzhen China
Cod.16328 rev. 06/2014
WARRANTY: The warranty terms here specified are valid only in Italy for Italian residents. In all other
countries, the warranty will be provided by GB the local dealer that sold you the unit, in accordance