DIRECTIONS

     followed by last recorded temperature. After showing the self-test temperature, the thermometer is 

     now in the testing mode.

1.  Press the

 

On/Off  

Button next to LCD display.  A tone will sound as the screen shows              , 

*Note:  If the measured temperature is less than  32  or 90 , the LCD will display Lo, if the measured
              temperature is higher than 42.9 or 109.9 , the LCD will display Hi.

2.  Position thermometer in desired location (mouth, rectum, or armpit.)  

     a)  

O r al U se:

  Place thermometer under tongue as indicated by

           position shown in Figure 2.  Close your mouth and breathe evenly 

           through the nose to prevent the measurement from being influenced 

           by inhaled/exhaled air. Normal temperature between 35.7   and 37.3 

           (96.3  and 99.1 )

     b)  

R ectal U se:

  Lubricate silver probe tip with petroleum jelly for easy insertion.  Gently insert 

           sensor approximately 1cm (less than 1/2  ) into rectum.  Normal temperature between 36.2  

           and 37.7    (97.2  and 99.9 ).

     c)  

A r mpit U se: 

 Wipe armpit dry.  Place probe in armpit and keep arm pressed firmly at side.  

          From a medical viewpoint, this method will always provide inaccurate readings, and should not 

          be used if precise measurements are required. Normal temperature between 35.2   and 36.7 

         (95.4  and 98.1 ).

3.  The degree sign flashes throughout the testing process.  When flashing stops an alarm will beep for 

     approximately 10 seconds.  The measured reading will appear on the LCD simultaneously. The 

     minimum measurement time until the signaling tone (beep) must be maintained without exception. The 

     measurement continues even after the buzzer notification. The displayed temperature will not change 

     when thermometer is removed from its testing position.

4.  To prolong battery life, press the 

On/Off

  Button to turn unit off after testing is complete.  If no action 

      is taken, the unit will automatically shut off after around10 minutes.

5.  Store the thermometer in its protective case.

"

*Note:  Normally 

Alarm b eeps m ore ra pidly w hen te mperature  

              reaches 37.8  (100 ) or higher ,and t

              

the buzzes are

 Bi

-

Bi

-

Bi

-

B  i

-

;   

he  buzzes are

 Bi-Bi-Bi----- Bi-Bi-Bi------- Bi-Bi-Bi

 BATTERY REPLACEMENT

1.  Replace battery when

appears in the lower right corner of LCD display.

2.  Pull battery cover off as shown in Figure 3.
3.  Gently pull out plastic circuit board with battery chamber approximately 1 cm (slightly less than1/2  
     (See Figure 4)
4.  Use pointed object such as a pen to remove old battery.  Discard battery lawfully.  Replace with new 
     1.5V DC button type LR41 or SR41,UCC392, or equivalent.  Be sure battery is installed with 

polarity facing up.  (See Figure 5)

5.  Slide battery chamber back into place and attach cover.

      

".)

+

     

LIMITED WARRANTY

Figure 2

The warranty terms here specified are valid only in Italy for Italian residents. In all other countries, the warranty will 

be provided by GB the local dealer that sold you the unit, in accordance with the applicable laws.

0197

Hangzhou Sejoy Electronics &.Instruments Co., Ltd.

Building 2, No.202,Zhenzhong Road, West Lake Economy & Technology Zone 310030 Hangzhou China
Shanghai International Holding Corp.GmbH(Hamburg)

Eiffestrasse 80, 20537 Hamburg, Germany

EC

REP

M

Disposal of this product and used batteries should be carried out 

in accordance with the national regulations forthe disposal of 

electronic products.

The product is in compliance with the requirements 

of MDD 93/42/EEC, "0197" is the identification 

number of notify body.

Document No. DMT-7104-012 

Version: Z

Date of Issue: 2015.05

CLEANING AND DISINFECTION

For stubborn stains, wipe the thermometer with a cloth that has been dampened with water or a

neutral detergent solution and then wring thoroughly. Finish by wiping with a soft dry cloth.

For disinfection, 70% Ethanol or Isopropyl alcohol can be used.

Observe the following to prevent damage to the thermometer.

-Do not use benzene, thinner, gasoline or other strong solvents to clean the thermometer.

-Do not attempt to disinfect the sensing section (tip) of the thermometer by immersing in 

  alcohol or in hot water (water over 5

0

(122

))

.

-Do not use ultrasonic washing to clean the thermometer.

wipe the thermometer with a soft clean cloth.

 SWITCHABLE 

Temperature readings are available in the Fahrenheit or Celsius scale (

/

; located in the upper right 

corner of LCD.)  With the unit off, press and hold the

 On/Off  

Button for approximately 4 seconds to

change the current setting.

 

PRECAUTION

*

The performance of the device may be degraded should one or more of the following occur:

- Operation outside the manufacturer’s s tated te mperature and humidity range.

- Storage outside the manufacturer’s s tated te mperature and humidity range.

- Mechanical shock (for example, drop test).

- Patient temperature is below ambient temperature.

*Portable and mobile RF communications can affect the device. The device needs special pre-cautions

   regarding EMC according to the EMC information provided in the accompany documents.

DIGITAL THERMOMETER

This digital thermometer provides a quick and highly accurate reading of an individual's body 

temperature. The digital thermometer  is intended to measure the human body temperature in 

regular mode orally, rectally or under the arm, and the devices are reusable for clinical or home 

use on people of all ages. To better understand its functions and to provide years of dependable 

results, please read all instructions first.

This appliance conforms to the following standards:

EN 12470-3 Clinical thermometers —Part 3: Performance of compact electrical thermometers 

(non-predictive and predictive) with maximum device,

ISO 80601-2-56 Medical electrical equipment —Part 2-56:Particular requirements for basic safety 

and essential performance of clinical thermometers for body temperature measurement,

EN 60601-1-11 Medical electrical equipment —Part 1-11: General requirements for basic safety and

essential performance – Collateral Standard: Requirements for medical electrical equipment and 

medical electrical systems used in the home healthcare environment and complies with the 

requirements of EN 60601-1-2(EMC), IEC/EN 60601-1(Safety) standards. And the manufacturer is 

ISO 13485 certified.

 

PLEASE  READ  CAREFULLY  BEFORE  USING

PRODUCT  ILLUSTRATION

CONTENTS

Wa r ning : 

 

OWNER S M

   ANUAL

1 Thermometer,  1 Owner s Manual,  1 Storage Case

Model:MT-31

Read instructions thoroughly before using digital thermometer.

Choking Hazard:  Thermometer cap and battery may be fatal if swallowed.  Do not allow children

to use this device without parental supervision.

Do not use thermometer in ear.  Designed use is for oral, rectal, and armpit (axilla) readings only.

Do not place thermometer battery near extreme heat as it may explode.

Remove battery from the device when not in operation for a long time.

  

Note: Use of the probe cover may result in a 0.1

(0.2

) discrepancy from actual temperature.

It is recommended the performance should be checked every two years.

The  use of temperature readings for self-diagnosis is dangerous.  Consult your doctor for the

interpretation of results. Self-diagnosis may lead to the worsening of existing disease conditions.

Do not attempt measurements when the thermometer is wet as inaccurate readings may  result.

Do not bite the thermometer. Doing so may lead to breakage and/or injury.

Do not attempt to disassemble or repair the thermometer. Doing so may result in inaccurate readings.

After each use, disinfect the thermometer especially in case the device is used by more than one person.

Do not force the thermometer into the rectum. Stop insertion and abort the measurement when pain is

present. Failure to do so may lead to injury.

Do not use thermometer orally after being used rectally.

For children who are two years old or younger, please do not use the devices orally. 

SPECIFICATIONS

SYMBOL EXPLANATION

Measure Range:

Accuracy:

Operating mode:                        Direct Mode

Display:

Memory:

Battery:

Battery life:

Dimension:

Weight:

Ambient operating range:

Storage and transportation 

condition:

32.0

℃-

42.9

(90.0

-109.9

)( 

 /

  chosen by manufacturer)

±

0.1

(0.2

) during 35.5

~42.0

(95.9

~107.6

) at

18

~28

 (64.4

~82.4

 ) ambient operating range

±

0.2

(0.4

) for other measuring and ambient operating range

Procedures for determining the accuracy of the thermometer are

available upon request.

Liquid crystal display, 3 1/2 digits

For storing the last measured value

One 1.5 V DC. button battery (size LR41or SR41, UCC 392)

Approx 200 hours

13.0cm x 1.9cm x 1.0cm (L x W x H)

Approx. 12 grams including battery

Temperature: 

(

)

5

℃~

40

41

℉~

104

Relative humidity: 15%~95%RH

Temperature: 

(

)

-20

~55

-4

℉~

131

Relative humidity: 15%~95%RH

Type BF

Classification:

Type:

Digital Thermometer (Not Predictive)

Battery Cap

O n/O ff

  Button

LCD

Probe

Figure 1 

 Direct Current 

Consult Accompanying Documents

 Type BF  Applied Part

Batch code
Manufacturerer

EC

REP

European Authorized Representative

Figure 4

Figure 5

Figure 3

Keep Dry

Cod. 17825 Rev.06/2017

Distribuito da / distribuited by:

FLAEM NUOVA S.p.A. - Via Colli Storici, 221

25015 S. Martino della Battaglia (BS) Italy 

www.flaem.it