Compressor
•
The compressor must be secured by using the supplied safety chain; fasten the chain through
the S shaped hook and anchor its ends to fixed points of the tractor (picture no. 3).
•
Complete the installation by introducing the suction air hose inside the bayonet connector (pic
-
ture no. 4).
Operating Instructions:
For the compressor correct use, operating in the following way:
•
Check the correct installation (see picture no. 5)
• Make sure the delivery pipe is properly connected
• Slowly rotate the shaft, avoiding snatches or shocks on the entire application.
• Conduct a short running-in at low speed
• During the tank charging period, monitor the pression indicated on the manometer. Wait until it
reaches the value of 8 bars, when the safety valve should release.
•
Once checked the whole system efficiency, you can withdraw air from the tank.
WARRANTY!
in case the installation is not sufficiently stable do not proceed, but try to stretch the
chains much more, obviously with engine off. In case the safety valve does not release, proceed to
the replacement. Do not insist, the pressure reached here could be extremely high and dangerous.
While using the compressor, avoid the following manoeuvres and comply with the following directi-
ons:
•
In the starting phase, move people and animals away from the tractor. NON DO NOT LEAVE
ANY OBJECT AND CLOTHING CLOSE TO THE ROTATING SHAFT
• Avoid sudden accelerations and/or decelerations of the shaft
• Make sure not to crush the delivery pipe during operation
• Avoid operating on the compressor without lubricating
After using the compressor, demount it and operate as follows:
•
Switch off the tractor and remove the delivery pipe from the compressor
•
Wait the compressor to cool until it reaches not dangerous temperatures (aprox. 34/40 C°
max.)
•
Unhook the tractor safety chain, release the socket cup of the PTO shaft and remove the com
-
pressor from the tractor PTO. Take off the pipes from the mouths, unhook the chain and remo
-
ve the pump from the power take-off.
WARNING!
In case you have reached or exceeded 10 hours of work, grease (through the two
lubricators) before putting the compressor to rest. Handle with care to avoid shocks on the com
-
pressor compression shaft as well as on the tank.
Maintenance:
Routine and preventive maintenance
•
Clean the compressor especially the aspiration filters placed on the heads
• Check the correct tightening of the compressor screws
• Check the fastening of the socket cup on the threaded sleeve to the compressor compressing
shaft
•
The operations as perchapter „Operation Instructions“ are to be considered of ordinary mainte
-
nance
• Every 10 hours of work, lubricate the compressor with the same grease normally used for agri-
cultural machinery