USER MANUAL
MACHINE OVERVIEW
OPTIMAL VOLTAGE
The Spektra Edge will run on any high quality rotary compatible power supply from 6v-12v depending on the brand
of needle cartridge and grouping that are used. Optimal voltage for the machine is generally achieved between
7.5-10v. Be aware that it is not suggested to run the machine above 12v to avoid over-working the skin due to the
high RPMs reached.
ADJUSTING THE GIVE
Your new machine comes with a fully adjustable needle resistance system (give.) To fully eliminate the “give” of
the machine turn the Give Adjustment Knob clockwise until it stops, being careful not to over torque the give knob
to prevent locking the slider.
If you prefer to work with give, simply turn the Give Adjustment knob counter-clockwise until the desired resistance
is achieved.
The Edge X has an effective 1.5-1.8mm of give travel that has been specifically designed to work with cartridge
style machines by taking into account the internal tension of the various needle cartridges. Starting with the knob
turned completely clockwise to the stopped position, turn the knob counter clockwise in 1/8 turn increments to
begin opening the give. 1.5 full counter clockwise turn of the knob will provide the full range of give achieved by the
machine. Do not turn the give knob beyond 1.5 full turns as this will result in no additional give and it will remove
the give knob completely.
Be aware that the give knob of the machine does not act as an armature, therefore, it will not serve as a tactile
indication of the give of the machine. You may also notice that different cartridges may require more or less
adjusting of the give knob to achieve the same results due to the varying internal tensions between cartridge
needle brands.
LUBRICATION
The slider of the Spektra Edge is made of an Acetal Resin that contains PTFE and Teflon in its composition.
This results in reduced friction and will ensure the overall smoothness and low vibration of the machine. To
prolong the life of the machine, it is recommended to apply lubricant to the slider at least once per month/
120 hours, or when the machine begins to provide audible indication that the slider has become dry and
thus causing additional friction.
To lubricate the machine you will apply 1 drop of the included lubricant at the base of the slider where it
meets the slider guard, or at the base of the give knob on the Edge X version of the machine. You will then run
the machine with a grip installed at 15v for 5-6 seconds in order to disperse the lubricant, and the process
is complete.
Be careful not to over-lubricate the machine as excess lubricant introduced into the tight tolerances may cause
decreased slider performance.