Fixturlaser GO Pro Manual 2
nd
edition
6.15
MEASUREMENT POINT
REGISTRATION
Set the sensors so that they are
approximately at the same rotational
angle at the first measurement position.
Select the register icon and
press OK.
This registers the first
reading.
Rotate the shafts to the next position.
The shafts must be rotated over a
minimum of 45°.
Green sector show permitted positions.
Red sector show forbidden positions.
The Register icon is not shown if the
rotation is less than 45°.