OPERATION & MAINTENANCE 

Wiring 

All  wiring  must  comply  with  applicable  codes  and 
standards.    See  unit  rating  label  for  correct  voltage  and 
amperage. 
1.  A knockout is provided on top of the unit, adjacent to 

the  wiring  compartment.    For  convenience,  a  wall 
switch may be installed near the Air Cleaner, in series 
with the power source, to turn the unit on and off. 

2.  Remove the cover of the wiring compartment to locate 

the  input  leads  and  ground  stud.    The  Air  Cleaner 
must be grounded for proper operation and safety. 

3.  Once the unit is mounted and wired, the cover can be 

replaced on the hinge and the chain replaced  on the 
"S" hooks.  Close the cover by sliding it forward, lifting 
the cover over the front flange and sliding it back into 
place. 

Operation Check

 

1.  With  the  cover  closed  and  in  place,  turn  the  system 

switch on. 

2.  Adjust the fan speed with the slide switch.  Insure the 

unit functions on all speeds. 

3.  The  Performance  Indicator  Light  should  be  lit,  which 

indicates the Power Board is functioning properly. 

When  the  Air  Cleaner  is  new  it  may  arc  or  periodically 
make "snapping sounds".  A slight  odor of ozone may be 
noticeable.  The arcing and odor are due to rough edges 
and  burrs  on  the  cells.    These  symptoms  will  disappear 
during the first few weeks of normal operation.  The ozone 
levels are well below government standards for indoor air 
concentration. 

Maintenance Schedule 

The Collecting Cells and Prefilters must be cleaned on a 
regular basis for the unit to function at its peak efficiency.  
The frequency of cleaning will vary from one environment 
to another.  The following is an average wash cycle: 

Stores,  Offices,  Computer  &  Conference  Rooms  = 

Weeks

 

Cafeterias, Restaurants, Lounges = 

3-4 Weeks

 

Bars, Bingo halls = 

1-3 Weeks

 

Cleaning & Service 

1.  Turn  off  the  system  switch  and  wait  15  seconds  for 

high voltage to dissipate. 

2.  Open  the  cover  and  cell  access  door  and  remove 

collecting cells and prefilters.  

Cell  plates  are  sharp.  

Handle with care.

 

3.  Place  Cells  in  tub  and  spray  completely  with 

DAX 

Detergent

, allowing detergent to run down both sides 

of  plates  and  ionizing  wires.    Let  sit  for  5  minutes.  
Rinse  Cells  well  with  hot  water  (140ºF  /  60ºC 
maximum).  Repeat washing process 3 times. 

4.  If  dirt  or  nicotine  remains  on  plates,  let  Cells  soak  in 

hot  soapy  water  for  30  minutes.   

Never  use  any 

instrument  to  clean  the  cell,  as  this  may  damage 
the ionizing wires or bend cell plates. 

5.  Spray Prefilters with 

DAX Detergent

 and rinse well. 

6.  To dry cells, tilt on 45º angle against wall with arrows 

pointing sideways.  Allow to dry completely for 10-24 
hours. Place in sunlight for faster drying time. 

7.  When  the  Cells  and  Prefilters  are  dry,  place  them 

back  into  the  unit.    The  arrow  on  the  cell  points  up.  
The red fiberboard on the Cell should line up with the 
contacts in the cabinet.  Close door and cover.  If the 
Cells  arc  when  the  switch  is  turned  on  or  if  the 
Performance  Indicator  Light  does  not  come  on,  then 
the Cells are still wet.  Allow more time for drying. 

The use of  

DAX  Detergent

 is strongly recommended for 

cleaning as it is a heavy-duty solution used expressly for 
removal of accumulated pollutants on Cell plates.  If used 
as  directed, 

DAX

  will  not  harm  aluminum  or  steel.    Any 

problem  arising  out  of  the  use  of  another  cleaning  agent 
will  void  the  warranty.    Do  not  use  detergents  that  are 
corrosive or abrasive or detergents containing chlorine or 
ammonia. 
 

DAX  Detergent 

is  available  in  1  gallon  (4.54L)  and  4.8 

gallon (22L) containers as well as 45 gallon drums (204L). 

Service Maintenance

 

1.  Determine if the Air Cleaner is performing properly by 

seeing that: 

System switch is 

ON

 

Performance indicator is 

ON

 

 
2.  A  simple  test  to  check  hi-voltage  would  be  to  blow 

dust  or  cigarette  ash  into  the  intake  grill.  An  audible 
arc  or  snapping  sound  should  be  heard,  ensuring 
good hi-voltage. 

 
3.  If  in  doubt,  and  if  the  Cells  are  not  collecting  any 

carbon  or  nicotine  tars,  then  see 

"Troubleshooting 

Guide"

 or consult your installation dealer. 

WARNING 

Electrical shock can cause injury or death. Be certain 
main line disconnect switch is off before wiring.  

CAUTION 

Make  sure  Air  Cleaner  switch  is 

OFF 

before 

performing  any  maintenance  or  removing  any 
components.  

CAUTION  

Damage  to  Cells  may  occur  if  improperly  handled  or 
washed.  Do  not  wash  Cells  in  a  dishwasher.  Never 
use  any  object  to  clean  between  the  cell  plates,  as 
this  may  cause  damage  to  plates  or  ionizing  wires. 
Never place cell in oven to dry. The edges of the cell 
may be sharp - handle with care.  

WARNING 

Electronic  Air  Cleaners  use  high  voltage  (low 
amperage).  Only  trained  personnel  should  perform 
service.  Use caution.  Electric shock can cause injury 
or death.  

Summary of Contents for SSCB15

Page 1: ...Operation And Maintenance Manual MODEL SSCB15 CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT ...

Page 2: ...ld spores fungi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employees reduce suffering from irritated eyes nasal congestion and respiratory problems that lead to absenteeism Helps prevent damaging black and greasy particles from staining ceilings walls and furnishi...

Page 3: ...TALLATION 1 Read instructions carefully Failure to do so may result in product damage or injury 2 Make sure the sizing is correct for your application 3 Installation should be done by a knowledgeable technician 4 After installation check out operation as provided in these instructions Mounting 1 Remove the unit from the box with packing still on the unit and lay it on its back grill side up 2 Rele...

Page 4: ...otine remains on plates let Cells soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or bend cell plates 5 Spray Prefilters with DAX Detergent and rinse well 6 To dry cells tilt on 45º angle against wall with arrows pointing sideways Allow to dry completely for 10 24 hours Place in sunlight for faster drying time 7 When the Cells...

Page 5: ...3 Unit cover is completely closed and locked into place 4 Power switch is ON Performance Indicator Light Is Not Lit 1 System switch is ON 2 Remove Cells close access door and turn unit ON If Performance Indicator is still off problem is in the power box If light comes on with no cells then there is a short circuit in the cells Place one cell in the unit close access door and turn unit ON If the li...

Page 6: ...Electrical Schematic B with Wired Remote 120 Volt Electrical Schematic A 120 Volt ...

Page 7: ...Electrical Schematic B with Wired Remote 220 240 Volt Electrical Schematic A 220 240 Volt ...

Page 8: ...s a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 4 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 5 Damage as a result of floods winds fires lightning accidents corrosive atmosphere or other conditions beyond the contro...

Reviews: