CLEANING INSTRUCTIONS

 

The prefilter and collecting cell must be washed on a regular 
basis  for  the  Air  Cleaner  to  function  at  its  peak  efficiency.  
The frequency of cleaning will vary from one environment to 
another,  therefore  the  cell  should  be  checked  monthly  to 
determine cleaning schedule.  On average, the cell should be 
washed every 2-3 months. 

 
COLLECTING CELL AND PREFILTER

 

1.  Turn  Air  Cleaner 

OFF

.    Remove  prefilter  and  collecting 

cell from the Air Cleaner. 

2.  Rinse  prefilter  and  collecting  cell,  and  spray  completely 

with 

DAX  Detergent

  (or  a  non-chlorine,  non-corrosive, 

non-abrasive, liquid household detergent).  Let stand for 
5  minutes.    Rinse  well  with  hot  water  (120°F  /  49°C 
maximum).  Repeat process 3 times. 

3.  If  dirt  remains,  let  cell  soak  in  a  solution  of  DAX 

Detergent and hot water for 30 minutes. 

4.  For  drying,  place  the  cell  on  a  45°  angle  on  one  end, 

with the arrow pointing sideways, and let stand for 10  - 
24 hours.  A hair dryer may be used to speed up drying 
time.    Make  sure  the  cell  is  completely  dry  before 
reinserting back into Air Cleaner.  The arrow on the cell 
must point up toward the fan blower. 

5.  If arcing or snapping occurs or the lights do not come on 

when the cell is placed back in the unit and turned on, 
then remove the cell and allow to dry longer. 

 

ODOR & GAS (VOC) REMOVAL FILTER 

1.  The Activated Carbon Odor & Gas (VOC) Removal Filter 

must be replaced at regular intervals if odour removal is 
desired  (approximately  every  3-6  months). 

ODOR REMOVAL FILTERS ARE NOT WASHABLE.

 

 

CABINET

 

1.  Turn Air Cleaner 

OFF

2.  A soft, damp, lint-free cloth may be used to remove dirt 

and fingerprints from painted surfaces and grills. 

NEVER  USE  AN  ABRASIVE  CLEANER  ON  THE 
CABINET.

 

 
WARNING 

DO 

NOT 

WASH 

COLLECTING 

CELL 

IN 

DISHWASHER

.

 

Never use any object to clean between the cell plates as 
this may cause damage to the plates or ionizing wires. 
Never place the cell in an oven to dry. 
The edges of the cell may be sharp.  Handle with care. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

DAX Detergent, No. 9900, and the Activated Carbon Odor & Gas 
(VOC) Removal Filter, No. 89-0810, are available from your retail 
outlet.

 

TROUBLESHOOTING CHART 

 
The two Operation Lights, located behind the front grill,   are 
also  used  as  the  high  voltage  fault  indicator.    If  the  fan  is 
operating,  but  the  lights  do  not  come  on,  then  there  is  a 
problem  in  the  high  voltage  circuit.    To  determine  the 
problem, turn the Air Cleaner 

OFF 

and remove the collecting 

cell.    Close  the  access  door  and  turn  the  Air  Cleaner  back 

ON

.    If  the  lights  come  back  on,  the  problem  lies  in  the 

collecting  cell.    Check  the  cell  for  wetness  from  washing  or 
look for a broken ionizing wire(s) or bent cell plate(s). 
 
If  the  lights  do  not  come  on,  the  problem  is  with  the  power 
board or Operation Light (s).  If you are unable to correct any 
of the above problems, call 1-800-267-8305.

 

 

TECHNICAL DATA 

 

PROBLEM 

CAUSE 

Fan does not operate 
Both Operation Lights off 

Unit not plugged in 
Screw not tight on access door 
System switch not 

ON

 

Green Performance  
Light on 
Red Ion Light off 

Negative Ion switch not in 

ON

 

position 

Fan operating 
Both Operation Lights off 

Cell wet from washing 
Short in cell (see below) 

Fan does not operate 
Green Performance 
Light on 

Speed selector switch not 
positioned correctly 
Fan motor malfunction 

Cell arcing excessively 

Cell wet from washing 
Cell plate(s) bent 
Cell dirty or large lint ball/hair 
caught in cell 
Broken ionizing wire 

Both Operation Lights on 
Cell not collecting dirt 

Arrow on cell not pointing up 

Cell does not go in far 
enough to allow the door 
to close 

The cell is inserted wrong. The 
cell should be inserted with the 
arrow pointing up toward the fan 
blower 

Dimensions 
With Castors 

Width 

Depth 

Height 

 
 

13.0 in 
19.0 in 
26.5 in 

 
 

33.0 cm 
48.3 cm 
67.3 cm 

Weight 

42.0 lbs 

19.1 kg 

Input Voltage 

120 V   60 Hz 

220 V   50 Hz 

220-240 V   50 Hz 

Power Consumption 
(max) 

 

114 Watts 

 

Air Flow 

High 

Medium 

Low 

 

350 cfm 
245 cfm 
170 cfm 

 

595 m³/hr 
416 m³/hr 
289 m³/hr 

Cell Output Voltage 

7000 VDC @ < 1 mA 

 

Collecting Cell 
Surface 

2079 in² 

13413 cm² 

Negative Ionizer 

-5000 VDC @ <.1 mA 

 

Negative Ion Output 

2 x 327.7 K/in³ 

2 x 20 K/cm³ 

Ideal for rooms up to:  
(1 room air change 
every 20 minutes in 
maximum room size) 

 

868 ft² 

 

79.9 m² 

Summary of Contents for 890AIV

Page 1: ...oke cooking smoke and grease and more down to 0 01 micron Activated Carbon Odor Gas VOC Removal Filter removes Volatile Organic Compounds emitted from common sources within the home and office Dual Negative Ionizer restores the air s natural ion balance Quiet 3 Speed Fan is comfortable for room occupants Performance Indicator Light shows Air Cleaner is operating properly at a glance Mobile Easily ...

Page 2: ...ll remove casters and install casters on bottom of unit 4 Remove all packaging from the unit Choose a suitable location to allow unobstructed circulation from front and top of unit The unit performs best when the back is against a wall This enhances air circulation Allow at least one inch 2 5 cm away from back wall 5 Operate Air Cleaner at voltage shown on back of unit 6 The controls for the Air C...

Page 3: ...he Activated Carbon Odor Gas VOC Removal Filter No 89 0810 are available from your retail outlet TROUBLESHOOTING CHART The two Operation Lights located behind the front grill are also used as the high voltage fault indicator If the fan is operating but the lights do not come on then there is a problem in the high voltage circuit To determine the problem turn the Air Cleaner OFF and remove the coll...

Page 4: ...oft surfaces i e beds sofas 12 Do not use the Air Cleaner when oxygen is being used or when combustible gases are present 13 The Air Cleaner has slots or openings in the cabinet for ventilation purposes to provide reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered 14 The Air Cleaner should be operated only from the type of power source i...

Reviews: