CLEANING INSTRUCTIONS

 

 

The prefilter and collecting cell must be washed on a regular 
basis  for  the  Air  Cleaner  to  function  at  its  peak  efficiency.  
The frequency of cleaning will vary from one environment to 
another,  therefore  the  cell  should  be  checked  monthly  to 
determine cleaning schedule.  On average, the cell should be 
washed every 2-3 months. 

 
COLLECTING CELL AND PREFILTER

 

1.  Turn  Air  Cleaner 

OFF

.    Remove  prefilter  and  collecting 

cell from the Air Cleaner. 

2.  Rinse  prefilter  and  collecting  cell,  and  spray  completely 

with DAX Detergent (or non-chlorine, non-corrosive, non-
abrasive,  non-ammonia,  liquid  household  detergent).  
Let stand for 5 minutes.  Rinse well with hot water (120°
F / 49°C maximum). Repeat process if necessary. 

3.  If  dirt  remains,  let  cell  soak  in  a  solution  of  DAX 

Detergent and hot water for 30 minutes. 

4.  For  drying,  place  the  cell  on  a  45°  angle  on  one  end, 

with the arrow pointing sideways, and let stand for 10-24 
hours.    A  hair  dryer  may  be  used  to  speed  up  drying 
time.    Make  sure  the  cell  is  completely  dry  before 
reinserting back into Air Cleaner. The cell is inserted with 
the arrow pointing back toward the fan blower.  

5.  If arcing or snapping occurs or the lights do not come on 

when  the  cell  is  placed  back  in  the  unit  and  turned  on, 
then remove the cell and allow to dry longer. 

ODOR & GAS (VOC) REMOVAL FILTER 

1.  The Activated Carbon Odor & Gas (VOC) Removal Filter 

must  be  replaced  at  regular  intervals  if  odor  removal  is 
desired  (approximately  every  3-6  months). 

ODOR REMOVAL FILTERS ARE NOT WASHABLE.

 

CABINET

 

1.  Turn Air Cleaner 

OFF

2.  A soft, damp, lint-free cloth may be used to remove dirt 

and fingerprints from painted surfaces and  grills. 

NEVER  USE  AN  ABRASIVE  CLEANER  ON  THE 
CABINET.

 

WARNING 

DO 

NOT 

WASH 

COLLECTING 

CELL 

IN 

DISHWASHER

.

 

Never use any object to clean between the cell plates as 
this may cause damage to the plates or ionizing wires. 
Never place the cell in an oven to dry. 
The edges of the cell may be sharp — handle with care. 

 
 
 
 
 
 
 
 

DAX Detergent, No. 9900, and 
the Activated Carbon Odor & Gas 
(VOC) Removal Filter, 
No. 68-0810, are available from 
your Dealer.

 

 
 
 
 
 
 

TROUBLESHOOTING CHART 

The  two  Operation  Lights,  located  behind  the  front  grill  are 
also  used  as  the  high  voltage  fault  indicator.    If  the  fan  is 
operating,  and  the  lights  do  not  come  on,  then  there  is  a 
problem  in  the  high  voltage  circuit.    To  determine  the 
problem, turn the Air Cleaner 

OFF 

and remove the collecting 

cell.  Close the top cover and replace the thumbscrew, then 
turn the Air Cleaner back 

ON

.  If the lights come back on, the 

problem lies in the collecting cell.  Check the cell for wetness 
from washing or look for a broken ionizing wire(s) or bent cell 
plate(s). 
 
If  the  lights  do  not  come  on,  the  problem  is  with  the  power 
board or the Operation Light(s).  If you are unable to correct 
any of the above problems, call your Dealer. 

TECHNICAL DATA 

PROBLEM 

CAUSE 

Fan does not operate 
Both Operation Lights off 

Unit not plugged in 
Top panel thumbscrew not 
tightened completely 
System switch not 

ON

 

Green Performance 
Light on 
Red Ion Light off 

Negative  Ion  switch  not  in 

ON 

position 

Fan does not operate 
Green Performance 
Light on 

Speed selector switch not 
positioned correctly 
Fan motor malfunction 

Fan operating  
Both Operation Lights off 

Cell wet from washing 
Short in cell (see below) 

Cell arcing excessively 

Cell wet from washing 
Cell plate(s) bent 
Cell dirty or large lint ball/ hair 
caught in cell 
Broken ionizing wire 

Cell does not go in far 
enough to allow top 
cover to close 

Cell is inserted wrong. Cell should 
be  inserted  with  arrow  pointing 
back toward fan blower 

Dimensions 

Width 

Depth 

Height 

 

10.2 in 
12.3 in 

18 in 

 

25.9 cm 
31.2 cm 
45.7 cm 

Weight 

26.0 lbs 

11.8 kg 

Input Voltage 

220-240 V  50 Hz 

220-240 V  50 Hz 

Power 
Consumption 
(maximum) 

 

85 Watts 

Air Flow 

High 

Medium 

Low 

 

130 cfm 

80 cfm 
60 cfm 

 

221 m³/hr 
136 m³/hr 
102 m³/hr 

Cell Output Voltage 

7000 VDC @ < 1 mA  

Collecting Cell 
Surface 

1417.5 in² 

9145 cm² 

Negative Ionizer 

-5000 VDC @ < .1 mA 

Negative Ion 
Output 

2 x 327.7 K/in³ 

2 x 20 K/cm³ 

Ideal for rooms up 
to:  (for 1 room air 
change every 20 
minutes) 

 

320 ft² 

 

29.5 m² 

Summary of Contents for 680AIV-2

Page 1: ...eria viruses tobacco smoke cooking smoke and grease and more down to 0 01 micron Activated Carbon Odor Gas VOC Removal Filter removes Volatile Organic Compounds emitted from common sources within the home and office Dual Negative Ionizer restores the air s natural ion balance Quiet 3 Speed Fan is comfortable for room occupants Performance Indicator Light shows Air Cleaner is operating properly at ...

Page 2: ...arises to store or transport the unit 3 Remove all packaging from the unit Choose a suitable location to allow unobstructed circulation from the front and back of the unit If unit has to be placed against a wall allow at least 6 8 inches 15 20 cm for circulation 4 Operate Air Cleaner at voltage shown on back of unit 5 The controls for the Air Cleaner are located on the rear panel To turn the Air C...

Page 3: ...cell may be sharp handle with care DAX Detergent No 9900 and the Activated Carbon Odor Gas VOC Removal Filter No 68 0810 are available from your Dealer TROUBLESHOOTING CHART The two Operation Lights located behind the front grill are also used as the high voltage fault indicator If the fan is operating and the lights do not come on then there is a problem in the high voltage circuit To determine t...

Page 4: ... soft surfaces i e beds sofas 12 Do not use the Air Cleaner when oxygen is being used or when combustible gases are present 13 The Air Cleaner has slots or openings in the cabinet for ventilation purposes to provide reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered 14 The Air Cleaner should be operated only from the type of power source...

Reviews: