background image

Wireless Microphone System Operating Manual 

3. RECEIVER INSTALLATION 

Audio output connection 

There are two audio output sockets on the rear panel of the receiver. A 6.35mm Jack to Jack 
cable is supplied as standard and will connect into most Mic/Line Mixers including our 
Fitness Audio Aeromix line as per Fig 2. When 
connected with a jack to jack cable the volume 
control on the front of the receiver works as a 
"turn down" control should you need to adjust 
the mic volume for a signal processor. The 12 
o'clock position is approximately the same level 
as using a balanced XLR cable. 

When you connect using an XLR balanced cable 
the signal level is fixed. It is the same level as 
plugging a cabled microphone to the same 
input and it by-passes the front panel volume 
control.   

Rack Mounting the Receiver 

The Fitness Audio U & V Series Receivers are a 19” half-rack mount design and is supplied 
with a specially designed 19” rack mount “wings” that can be bolted into equipment 
cabinets. 

Assemble as shown in Fig 3. We have also supplied you with a pair of antenna extension 
cables so that the two antennas can be mounted into the holes on the rack ears out front in 
the air and not trapped inside a steel box. Use the star washer and the nut on the inside of 
the rack ears to get a firm non-slipping mount. 

A double receiver rack mount kit is available as an optional extra if required (Fig 4). 

Positioning the Receiver 

For best operation, the receiver should be at least 1m above the ground and at least 1m 
away from a wall or metal surface to minimise RF reflections. 

 

 

Summary of Contents for V Series

Page 1: ...OPERATING MANUAL FITNESS AUDIO U Series Wireless Mic System SDR 5616 Receiver SM 716 MT U8 Transmitter V Series Wireless Mic System SDR 1204 Receiver M 209C Transmitter ...

Page 2: ...iversity Indicator 4 AF Signal Indicator 5 RF test Button 6 Channel Selector 7 Volume Control 8 Antenna B Socket 9 Fixed Mic level Balanced output 10 Unbalanced Variable Line level output 11 Squelch Control 12 DC IN Jack 13 Antenna A socket RF Test To find the best channel for transmission ensure the receiver is connected to a mixer and amplifier and press the RF Test button 5 If interference is h...

Page 3: ...s plugging a cabled microphone to the same input and it by passes the front panel volume control Rack Mounting the Receiver The Fitness Audio U V Series Receivers are a 19 half rack mount design and is supplied with a specially designed 19 rack mount wings that can be bolted into equipment cabinets Assemble as shown in Fig 3 We have also supplied you with a pair of antenna extension cables so that...

Page 4: ...eromic Cyclemic or E Mic then make sure the MT trimpot is turned up to the maximum Due to minor variations in the casing sizes of many brands of 9V batteries the transmitter battery compartment of the SM 716 is designed to accommodate the preferred 9V size battery made by Eveready the Energiser 9V Alkaline but other brands may also work well Re chargeable Ni MH batteries 170 190mAH ratings may nee...

Page 5: ...mation There will be different non conflicting channels in other frequency groups supplied around the world so please check with your dealer or national supplier for this information Fit a quality AAA battery into the battery compartment re fit the lid and push the sealed on off button A blue LED illuminates to let you know it s on When the LED starts flashing the power is running low and it s tim...

Page 6: ...ent or non Government operation the wireless microphone must cease operation The above statement is valid for the U S A Receiver Squelch control The squelch control on the back panel of the receiver is preset at the factory but can be adjusted if you use the system in a high RF interference area If there is audio output from the receiver when your transmitter is OFF adjust the squelch control so t...

Page 7: ...r green Battery Low Indicator red 3 Power on off switch SQ 5016 SQ 1016V SQ 1 Capsule with metal grille 2 Battery Good Indicator green Battery Low Indicator red 3 Power on off switch 4 LCD display SQ 5016 1 2 3 4 ess Microphone System Operating Manual Handheld mics are available for both Fitness Audio U and V Series Receivers contact your Please note that you can only use one mic transmitter at a ...

Page 8: ...e device This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l appareil doit accepter tout brouillage radioélectrique subi même ...