Professional Breath Alcohol Analyzer 

                                                                                                With Fuel Cell Sensor

 

                                                                           

 

FiT333 

 
 
 
 

  

  

  

  

IMPORTANT:  Many  factors  (e.g.  environment  gas  residue,  smoke  &  various  smell 

in human mouth, etc…) may affect the Blood Alcohol Concentration (BAC) level, so 

the Readings are For Reference Only. 

Neither the reseller nor manufacturer accept any liability arising from the use of this 

unit. 

DO NOT drink before you drive! 

www.aap.com.hk

   

 

Summary of Contents for FiT333

Page 1: ...environment gas residue smoke various smell in human mouth etc may affect the Blood Alcohol Concentration BAC level so the Readings are For Reference Only Neither the reseller nor manufacturer accept...

Page 2: ...Maintenance 4 Intended Use 4 Preparation 5 Power Charging 5 Operation instructions 6 Formal Test 6 9 Quick start 9 System Setting 9 10 Test record 11 Sensor Test 11 PC download 12 16 Change the wirele...

Page 3: ...easuring instrument 1 TFT QVGA 3 5 display with touch panel 2 Power Key 3 Back Key 4 OK Button 5 UP Key 6 Right Key 7 Down Key 8 Left Key 9 Mouth piece 10 Inner tube 11 USB Jack Connect computer 12 Pr...

Page 4: ...1pc 4 Wireless receive module 1pc 5 Wireless Launch module 1pc 6 Leather sheath 1pc 7 Printer paper 4pcs 8 PC download cable 1pc 9 Car adaptor connect the unit machine directly charging in the car 1pc...

Page 5: ...se Don t put this product in high temperature high humidity or high dust environment Don t knock this product especially do not press the TFT LCD by force Don t dismantle the machine and use the alcoh...

Page 6: ...the battery cover Power Charging If the battery symbol on the display indicates empty please charge it as soon as possible Pull out battery and put in the provided power adaptor to charge Or connect...

Page 7: ...inuous Beep sound announcement Active test ii Manual test If user cannot perform the automatic test Driver do not provide continuously breath blow press the OK key once to take sample Passive test 1 3...

Page 8: ...result will then be shown on the display after analyzing 1 5 Press Retest icon to start another test or press Save to input the relevant information Press Exit to return back into the main menu 1 6 If...

Page 9: ...nvironment residue the machine should rest for 3 minutes for each quick test Also need to change the mouthpiece for each test Push the REJECT trigger 1 8 Change new mouthpiece Remove and change a new...

Page 10: ...ystem Information Advanced Setting Caution The calibration is already been done before shipping user alters the setting parameters will override all calibration data Only FiT authorized technician is...

Page 11: ...s required In this mode user can set the as follow information A conversion rate for mg L B Airflow C Alcohol Calibrate Available for Service Center only Enter the calibration mode by input the superv...

Page 12: ...sword similar to advanced setting password 5 Sensor Test Press Sensor Test icon and blow alcohol breath about 0 05 BAC into chamber through the blow tube for about six seconds and observe the sensor s...

Page 13: ...the download cable to connect the computer Step 2 Please copy all the files under the content of FiT333 from the optical disk into computer Remark have to run the download software after copy all the...

Page 14: ...11 12 13 Step 6 Open the Removable disk in the computer find and click FiT_TestRecord exe file then will see the interface as picture below Step 7 Click File and select Load to upload the data to com...

Page 15: ...FiT333 333 15Y07526 2015 11 12 14 To input the User 000000 and Password 000000 as below picture User and Password is ok display as below picture To click confirm return to below picture...

Page 16: ...FiT333 333 15Y07526 2015 11 12 15 Step 8 Click File and select Load again to upload the data to computer as picture below...

Page 17: ...ice software to process the uploaded test record data PS Please copy the file under the FiT333 file list of the CD into the computer disk and run CD ROM FiT_TestRecord exe or register manually to have...

Page 18: ...printer can be connected to a wireless module and become a wireless printer Use the provided car adaptor and connect to car cigarette plug Then use the wireless printer to printing the test result as...

Page 19: ...nized by e mailing sales aap com hk 11 How often should I re calibrate the FiT tester The FiT tester can remain accurate for 1 year of use The more frequent the use the more the unit will need to be c...