DSP501N OPERATING MANUAL
P/N 561796N
REV. A OCT. 10
©2010 FISNAR, INC.
Specifications
Size:
8 ⅝” x 8 ½” x 2 ⅝”
(22 x 21 x 6.7cm)
Weight:
2.8 lbs. (1.3kg)
Input
Voltage:
90-260 VAC
Dispense
Time:
0.01 - 31 seconds
Internal
Voltage:
24VDC
Cycle
Initiation:
Maintained or
Momentary
Cycle Speed:
600+/min
Air Input:
70-100psi (5-7 bar)
Air Output:
1-100psi (0.1-7 bar)
Standards:
CE Approved
RoHS Compliant
Barrel “Suck-Back” Feature
Ordering Guide
Part No
Description
DSP501N
Multi Voltage
Dispenser
Standard Accessories
Qty
Description
Reorder P/N
Qty/
Pack
1
1
1
1
1
1
1
1
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
2
Detachable Power Cord 110 Volts
Detachable Power Cord 220 Volts
Detachable Power Cord 220 Volts
Barrel Stand
Backhose w/Clamp & Barb Fit
Foot Pedal Assembly
Barrel Adapter - 30cc - 3' (91.4cm) 1/4" Hose
Barrel Adapter - 5cc - 3' (91.4cm) 1/4" Hose
Barrel - 30cc - Bevel
Barrel - 5cc - Bevel
PE Piston - 30cc - Bevel
PE Piston - 5cc - Bevel
Tip Cap - Natural
Tapered Tip Double Helix - 14 Gage - Orange
Tapered Tip Double Helix - 16 Gage - Grey
Tapered Tip Double Helix - 18 Gage - Green
Tapered Tip Double Helix - 20 Gage - Pink
Tapered Tip Double Helix - 22 Gage - Blue
Tapered Tip Double Helix - 24 Gage - Red
Tip 1/2" Crimp Sealed - 20 Gage - Pink
Tip 1/2" Crimp Sealed - 21 Gage - Purple
Tip 1/2" Crimp Sealed - 22 Gage - Blue
Tip 1/2" Crimp Sealed - 23 Gage - Orange
Tip 1/2" Crimp Sealed - 25 Gage - Red
Tip 1/2" Crimp Sealed - 30 Gage - Lavender
560033-LF
560033E-LF
560033E-PLUG-LF
560751LF
560752
560027D
5601466
5601027
5601004
5601001
5601465
5601019
5601054
5601263
5601264
5601265
5601266
5601267
5601268
5601201
5601202
5601203
5601204
5601205
5601208
1
1
1
1
1
1
1
1
10
10
20
40
10
25
25
25
25
25
25
25
25
25
25
25
25
DSP501N
DISPENSE CONTROLLER
O
O
P
P
E
E
R
R
A
A
T
T
I
I
N
N
G
G
M
M
A
A
N
N
U
U
A
A
L
L
The
DSP501N
dispense
controller
incorporates a digital timer which can be
set to control the actuation of its high
duty-rate air solenoid.
Its higher volume exhaust prevents post-
dispensing compression of the material,
thus avoiding stringing. An internal
vacuum also comes standard to prevent
dripping of very low viscosity liquids.
Foot pedal initiation can either be for
maintained or momentary operation.
All hoses and fittings, along with barrels
and tips are already included, making the
unit ready to use right out
of the box.