5
This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation. Suitable for home or office use.
Warning. Do not expose this equipment to rain or moisture.
Attention. Ne pas exposer ce matériel à la pluie ou à l'humidité.
Name: Subwoofer SA Sub
Model: 494-000-366
Input: 100-120V~ 50/60Hz
Max. Power: 468Watts / 3.9A
Caution
: for continued protection against risk of fire,
replace only same type fuse.
Attention
: Pour assurer la protection contre le risque d’incendie,
veuillez utiliser un fusible de rechange du même type.
CONFORMS TO
UL STD. 60065
CERTIFIED TO
CSA STD C22.2
No. 60065
4006175
1
3
5
6
8
4
2
7
9
Controls (cont’d)
8. Phase –
It is recommended to start with this switch set to
Normal
, and
whenever in doubt, leave it in that position.
The
Inverted
setting can be used to phase align the crossover frequency
between sub and main speakers to compensate for unusual placement and
distance differences. This is only recommended for experienced professionals
with access to acoustic test equipment. When using multiple SA Sub’s, it is
recommended that
Phase
be set the same on all units. For example, Two SA
Sub’s set to opposite Phase in the same room will tend to cancel each other
in most locations, and should be avoided.
9. Front LED –
SA Sub has a Power indicator on both the front and back for
convenient viewing. In cases where the
Front LED
may be distracting, it can
be turned
Off
by setting the switch to that position.
On
Power
Off
Front LED
125Hz
80Hz
100Hz
GND
Lift
Output Ground
Off
On
LF Extension
Off − Power − On
Inverted
Normal
Phase
Volume
Signal/Limit
Input
Left
Right
Output
Left
Right
Designed and Engineered in the U.S.A.
by Fishman Transducers, Inc.
Assembled in China
Name: Subwoofer SA Sub
Model: 494-000-472
Input: 220-240V~ 50/60Hz
Max. Power: 468Watts / 2A
Warning
: Do not expose this
equipment to rain or moisture.
Attention
: Ne pas exposer ce
matériel à la pluie ou à l'humidité.
Fuse: T2.5AL 250V
Crossover
Low Pass Frequency
Caution:
For continued protection against risk of fire, replace only same type fuse.
Attention
: Pour assurer la protection contre le risque d’incendie, veuillez utiliser un fusible
de rechange du même type (For Finland only). Laite on liitettävä suojamaadoituskosketti-
milla varustettuun pistorasiaan (For Norway only). Apparatet må tilkoples jordet stikkontakt.
Apparaten skall anslutas till jordat uttag (For Sweden only).
120V