Table 3. Maximum Allowable Inlet Pressure for M35‐1 and CW2M Valve Bodies
(1)
TEMPERATURE
M35‐1
CW2M
150
300
600
(2)
150
300
600
(2)
_
C
Bar
-46 to 38
93
149
204
260
15.8
13.8
13.1
12.7
11.7
41.3
36.5
34.1
33.1
32.8
82.7
72.7
68.2
65.8
65.5
20.0
17.9
15.9
13.8
11.7
51.7
51.7
50.3
48.6
45.9
103.4
103.4
100.3
97.2
91.7
_
F
Psig
-50 to 100
200
300
400
500
230
200
190
185
170
600
530
495
480
475
1200
1055
990
955
950
290
260
230
200
170
750
750
730
705
665
1,500
1,500
1,455
1,410
1,330
1. M35‐1 and CW2M valve material are not included in ASME B16.34 pressure/temperature ratings. The designations 150 and 300 for this valve material are used only to indicate relative pres
sure/retaining capabilities and are not ASME pressure/temperature rated classes.
2. CL600 is only available in the NPS 2.
Table 4. Construction Material Temperature Limits
(1)
COMPONENTS AND MATERIALS OF CONSTRUCTION
TEMPERATURE LIMITS
_
C
_
F
Valve Body Material / Disc / Shaft Material
Carbon Steel / CF8M / S17400
Carbon Steel / CF8M / S20910
CF8M / CF8M / S17400
CF8M / CF8M / S20910
CG8M / CG8M / S20910
-29 to 427
-29 to 427
-73 to 427
-198 to 538
-198 to 538
-20 to 800
-20 to 800
-100 to 800
-325 to 1000
-325 to 1000
Bearing Material
PEEK / PTFE lined
Metal (NOVEX or Phoenix III only)
-73 to 260
-198 to 538
-100 to 500
-325 to 1000
Packing Material
PTFE V‐Rings
Graphite rings (NOVEX or Phoenix III only)
-46 to 232
-198 to 538
-50 to 450
-325 to 1000
Seal Ring
PTFE
(Standard) Soft Seal Ring
-46 to 232
-50 to 450
Reinforced PTFE
Soft Seal Ring
-46 to 232
-50 to 450
UHMWPE
Soft Seal Ring
-18 to 93
0 to 200
NOVEX
Metal Seal Ring
-46 to 538
-50 to 1000
Phoenix III
Metal Seal Ring
Fluorocarbon backup ring
-40 to 232
-40 to 450
Phoenix III Fire‐Tested
(2)
Metal Seal Ring
Fluorocarbon backup ring
(Specify metal bearings and graphite packing)
-40 to 232
(2)
-40 to 450
(2)
1. Refer to Ordering Matrix for 8560 Valves. For selection temperatures not shown above, contact your
Emerson sales office
or Local Business Partner.
2. For component selection and applicable fire‐tested standards and codes, consult your Emerson sales office or Local Business Partner.
1. Install a three‐valve bypass around the control valve assembly if continuous operation is necessary during
inspection and maintenance of the valve.
2. Inspect the valve to be certain that it is free of foreign material.
CAUTION
Be certain that adjacent pipelines are free of any foreign material, such as pipe scale or welding slag, that could damage the
valve sealing surfaces.