Service Manual 599337A: 302B Series Titan Oven
July 2006
29
Note:
To clear a fault code from the log push ‘CLEAR’ when it is displayed in the
temperature display.
4.4 Accessing Technical Data Log
1. Enter Technician Mode. (refer to Section 4.1)
2. Choose Tech Select option ‘DOWN LOAD’. (dial position 19)
3. Hold the Fisher & Paykel “Smart Tool” up to the clock module display (top left corner)
and press ‘CLEAR’ to initiate download.
4. Data can now be viewed on your PC.
4.5 Temperature
recalibration
If customer complains of oven performing too hot / cold, the temperature can be manually
adjusted by +/- 10°C (20°F) in increments of 1°C (2°F). This can be achieved by turning
the oven mode knob to position 20 in Technician mode and using the Temperature dial to
select the desired offset. Press the clock button to activate.
4.6 Technical Data Log
The Technical Data Log has a PC interface containing several sections of information.
These sections can be viewed as follows.
Info Section
This section contains general identification information for the oven.
Current / Previous Fault Information Sections
There are four sections displaying information on the two most recent fault codes for
each oven cavity. The information contained details the oven settings, electronic board
temperatures and the status of all oven outputs at the time the fault occurred.
Status Section
This section details all the current user settings and the electronic software and hardware
details. Also included are the following details:
Number of times each oven cavity was self-cleaned.
Clock module board maximum temperature.
The day maximum temperature occurred.
Number of days the oven has been in operation since the power-up.
Number of times the door has been opened.
Function Log Section
This section details the last ten oven modes used and the oven settings the user
selected.
Self-Clean Log Section
This will record the last five self-clean cycles.
The following data will be recorded when the oven cavity temperature exceeds 550°F
(288°C) and a self-clean cycle is set.
Day number the Self-Clean mode was used.
Heat up time between 550°F (288°C) and maximum temperature.
Maximum oven cavity temperature reached during Self-Clean.