5
FRONT ELEVATION
without front panels
DETAIL – PLAN VIEW
SIDE ELEVATION
with front panels
A
D
B
I
G
J
G
J
H
E
C
F
Ventilation of 50x560mm or totalling
280cm
2
is required for companion
products. The air vent must be located
at the rear of cabinet, it can be
positioned at the base, top, sides, or
back of the cavity.
Additional spacer
Sidewall of
appliance cabinet
Sidewall
of adjacent
cabinet
Front panel
of adjacent
cabinet
Steam/Speed Oven
Min
2mm
39mm
Critical rebate to
achieve flush finish
CAVITY DIMENSIONS
OM76 MODELS
MM
A
Minimum inside height of cavity
474
B
Minimum inside width of cavity
645
C
Minimum inside depth of cavity (from front of rebate)
560
D
Minimum height between cabinetry front panels
474
E
Overall width of cabinetry
762
F
Minimum overall depth of cavity (incl. front panel)
600
G
Rebate depth for flush install (incl. front panel)
39
H
Overall height of spacer in base of cavity
12
I
Ventilation gap
50
J
Minimum clearance to adjacent cabinetry or other appliances
2
CABINETRY DIMENSIONS (FLUSH INSTALL)