5
FRONT ELEVATION
without front panels
DETAIL – PLAN VIEW
SIDE ELEVATION
with front panels
A
D
B
I
G
J
G
J
H
E
C
F
Ventilation of 2" x 22 1/16" (50x560mm)
or totalling 43.4in
2
(280cm
2
) is required
for companion products. The air vent
must be located at the rear of cabinet,
it can be positioned at the base, top,
sides, or back of the cavity.
Additional spacer
Sidewall of
appliance cabinet
Sidewall
of adjacent
cabinet
Front panel
of adjacent
cabinet
Steam/Speed Oven
Min 1/16"
(2mm)
1 5/8"
(39mm)
Critical rebate to
achieve flush finish
CAVITY DIMENSIONS
OM30 MODELS
INCHES
MM
A
Minimum inside height of cavity
18 11/16
474
B
Minimum inside width of cavity
25 3/8
645
C
Minimum inside depth of cavity (from front of rebate)
22 1/16
560
D
Minimum height between cabinetry front panels
18 11/16
474
E
Overall width of cabinetry
30
762
F
Minimum overall depth of cavity (incl. front panel)
23 5/8
600
G
Rebate depth for flush install (incl. front panel)
1 9/16
39
H
Overall height of spacer in base of cavity
1/2
12
I
Ventilation gap
2
50
J
Minimum clearance to adjacent cabinetry or other appliances
1/16
2
CABINETRY DIMENSIONS (FLUSH INSTALL)