Fisher & Paykel PROFESSIONAL 9 Series Installation Manual Download Page 3

Before installation, please ensure the following:

 

y

The countertop is made of a heat resistant material.

 

y

The power supply cable is not accessible through cupboard doors or drawers.

 

y

There is adequate flow of cool air from the cabinetry to the base of the cooktop. You 
may ventilate from adjacent cupboards, but ensure that the available air supply will not 
be restricted.

 

y

The ventilation area must be at least two 2" (50mm) diameter holes or of equivalent area.

 

y

The isolating switch is easily accessible by the customer.

 

y

Use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the wall surfaces 
surrounding the cooktop.

 

y

DO NOT install the cooktop directly above a dishwasher, fridge, freezer, washing machine or 
clothes dryer, as the humidity may damage the cooktop electronics.

 

y

If the cooktop is installed above an oven, ensure the oven has a built-in cooling fan.

 

y

Ensure the installation complies with all clearance requirements and applicable standards 
and regulations.

 

y

Consult your local building authorities and by-laws if in doubt regarding the installation.

 

y

To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage 
space located above the surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a rangehood that projects horizontally a 
minimum of 5" (127mm) beyond the bottom of the overhead cabinets. 

During installation, please ensure the following:

 

 

y

Seal the exposed bare edges of the cutout with an oil-based paint or moisture-proof 
polyurethane to prevent possible moisture creeping between the cooktop trim and 
the countertop.

 

y

Take extreme care not to chip, crack, or break the top glass surfaces during installation. 
A heavy metal tool or part accidentally dropped on the glass could damage it. 

 

y

If, after following the instructions given, correct performance cannot be achieved, please 
contact your nearest Fisher & Paykel Service Centre, Customer Care, or contact us through 
our local website listed at the end of this document.

INITIAL CONSIDERATIONS

3/16" 

(5mm)

PRIOR TO INSTALLATION

MULTIPLE PRODUCT INSTALLATION

We recommend installing products in separate cutouts with a minimum distance of 3/16" 
(5mm) between the glass edges. If installing multiple products within the same cutout adjacent 
to each other, a joining strip kit is required. This kit creates a non non-visual, structural join 
between the two cooktops that ensures the weight of both cooktops is sufficiently supported. 
Joining strip kits can be purchased separately through an authorised Fisher & Paykel dealer. 
Visit fisherpaykel.com for more information.
The minimum clearance measurements for different products may vary. Always use the greater 
distance when pairing different products (eg an induction model and wok burner model).

33

Summary of Contents for PROFESSIONAL 9 Series

Page 1: ...BLACK INDUCTION COOKTOP CI304PTX CI365PTX models INSTALLATION GUIDE US CA...

Page 2: ...llation of appliances Incorrect installation may result in personal injury damage to property and may invalidate any warranty or liability claims z Do not modify this appliance z Do not use or store f...

Page 3: ...alling a rangehood that projects horizontally a minimum of 5 127mm beyond the bottom of the overhead cabinets During installation please ensure the following y Seal the exposed bare edges of the cutou...

Page 4: ...Clamping brackets 4 and screws 4 Wrench Hex key Foam tape 1 Crosshead screwdriver Router Silicone Cutter COMPONENTS REQUIRED PARTS SUPPLIED TOOLS REQUIRED 4...

Page 5: ...A Overall height of cooktop 3 13 16 97 B Overall width of cooktop 30 762 C Overall depth of cooktop 21 533 D Height of chassis 2 1 16 53 E Width of chassis 28 3 8 720 F Depth of chassis 19 482 G Heigh...

Page 6: ...Overall height of cooktop 3 3 8 86 B Overall width of cooktop 35 3 8 899 C Overall depth of cooktop 20 7 8 530 D Height of chassis 2 50 E Width of chassis 33 3 4 858 F Depth of chassis 19 1 16 484 G...

Page 7: ...C Corner radius of cutout max 3 8 max 10 D Offset overhang allowance 1 9 16 39 30 MODEL CUTOUT DIMENSIONS CI365PTX IN MM A Overall width of cutout 34 1 4 870 B Overall depth of cutout 19 7 16 494 C Co...

Page 8: ...F Minimum clearance from countertop to overhead cabinet not directly above the cooktop 23 1 2 450 G Maximum depth of overhead cabinetry 13 330 H Minimum distance between overhead cabinets either side...

Page 9: ...ion box 9 230 F Minimum clearance from countertop to overhead cabinet not directly above the cooktop 23 1 2 450 G Maximum depth of overhead cabinetry 13 330 H Minimum distance between overhead cabinet...

Page 10: ...IMENSIONS IN MM A Minimum ventiliation gap at the front of the cooktop 3 16 4 B Minimum clearance from bottom of chassis to drawer or other obstruction 2 9 16 65 C Minimum ventiliation gap at the rear...

Page 11: ...harp cutter or trimmer knife Take care not to damage the benchtop 4 Gently lower the cooktop into the cutout ensuring you have access below the countertop to fit and secure the brackets 5 Locate the s...

Page 12: ...nduit connector Junction box 3 wire cable from power supply White wire Black wires Red wire Green Yellow wire CSA or UL listed conduit connector Junction box 4 wire cable from power supply White wire...

Page 13: ...Complete and keep for safe reference Model Serial No Purchase Date Purchaser Dealer Address Installer s Name Installer s Signature Installation Company Installation Date Check that all the cooking zo...

Page 14: ...ge at any time The product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications...