You MUST use the Stability Anti-tip bracket to prevent unit from tipping.
Connecting the Power Supply Cable
This cooker must be connected to the electricity supply only by an authorized person.
Your cooker is supplied with a certified 4 prong NEMA 14-50P power cord and should be plugged directly into a properly
grounded socket. Do not under any circumstances cut or remove the forth (ground) prong from the power plug. Do not
ground to a gas pipe.
Do not have a fuse in the neutral or ground circuit.
Do not use an extension cord.
Check with a qualified electrical installer if you are not sure if the range is properly grounded.
If codes permit, and a separate ground wire is used, it is recommended that a qualified electrical technician determines
the ground path and wire gauge are in accordance with local codes.
Be sure that the electrical connection and wire size are adequate and in conformance with: ANSI/NFPA 70 latest
addition and local codes and ordinances;
CSA standard C22.1, Canadian Electrical Code, Part 1 - latest edition and local codes and ordinances.
https://producthelp.fisherpaykel.com/us/Cook/Ranges/Electric/OR30SDPWSX1/User_Guide_OR30SDPWSX1/02_installation_instructions
Updated: Fri, 08 Mar 2019 10:04:01 GMT
Powered by
8