Full Engineer Test Mode
This special mode is for testing single components of the control board. It can only be activated
within 10 seconds of the power being supplied and as soon as the cavity temperature has been
evaluated.
If the cavity temperature is higher than the door locking temperature, the door gets locked and the
test mode cannot be entered.
To enter test mode, turn on the appliance and within 10 seconds, turn the mode selector switch to
the ‘Self-Clean’ position and press timer buttons 5 and 6 together.
The display reads ”tE” for test mode.
To exit test mode and return to power on mode, press timer buttons 5 and 6 again. If no button is
pressed within 25 seconds, the test mode is automatically abandoned and the control returns to
power on mode.
The test mode is performed in 3 levels:
Level 0
Outputs, button and function test. Also program information.
Level 1
Inputs
test
Level 2
Analogue (AD) values test
**
When entering the test mode, the default level is level 0. To change the level, keep timer buttons
2 and 3 pressed.
The display reads "tE °x" while the degree sign flashes. Pressing the PLUS/MINUS key will set the
actual test level 0, 1, or 2.
**Test level 2 is not mentioned in this section as it is only applicable to the internal software
configuration and is not considered relevant to general service and repair work.
Level 0
This test is performed pressing the timer buttons as follows:
Button 1
Display and Buzzer test.
(Each press of the button moves to the next step.)
Step 1
All segments and symbols are illuminated and the buzzer sounds.
Step 2
All odd segments (A, C, E, G) and symbols (Bell, Pot, AUTO) are illuminated.
Step 3
All even segments (B, D, F) and symbols (P, AUTO), Dot, Celsius-Symbol) are
illuminated.
Button 2
Relay 1 (Thermostat) function test.
Display message ”tE E1” (listen for click of
relay
to confirm operation).
Button 3
Relay 2 (Main Oven Fan) function test.
Display message ”tE E2” (Listen for click of relay and observe main oven fan operation).
Button 4
Same as key 1
Button 5
Relay 3 (Lock / Unlock Relay) function test.
Display message ”tE E3” (Listen for click of relay and look at lock neon to confirm operation).
Button 6
Relay 4 / Triac 1 (Cooling Fan) function test.
Display message ”tE E4” (observe cooling fan operation).
Button 1 & 3 Program number (30-xxxx).
Display message ”1009”/”1082” for 50/60Hz version.
Button 1 & 5 Oven type.
i.e. valid oven temperature offset table A or B. Displays message "a" or "b".
Summary of Contents for OB24SDPX1
Page 1: ...599468 Service Manual Built in Ovens Model OB24SDPX1...
Page 15: ...599468 15 5 1 1 3 Wiring Diagram Old Version Programmer...
Page 16: ...599468 16 5 1 1 4 Wiring Diagram New Version Programmer...
Page 22: ...599468 22 5 1 2 5 Door Lock Status Wiring Diagrams...
Page 23: ...599468 23...
Page 24: ...599468 24...
Page 25: ...599468 25...
Page 26: ...599468 26...
Page 27: ...599468 27 5 2 Wiring Diagram...
Page 28: ...599468 28 6 FAULT CODES 6 1 Electronic Oven Fault Codes...
Page 30: ...599468 30 6 2 Pyrolytic Oven Fault Codes...
Page 31: ...599468 31...
Page 33: ......