6
8
SECURE THE OVEN TO THE CABINETRY
Oven may vary
1
Position the oven in the prepared cavity.
IMPORTANT!
Do not lift the oven by the door handle.
2
Open the oven door fully.
3
Mark and pre-drill the screw holes.
4
Use the supplied screws to secure the oven to the cabinetry.
IMPORTANT!
●
Do not over-tighten the screws.
●
Do not seal the oven into the cabinetry with silicone or glue. This makes
future servicing difficult. Fisher & Paykel will not cover the costs of
removing the oven, or of damage caused by this removal.
8
ELECTRICAL CONNECTION TO JUNCTION BOX
Junction box
location for:
undercounter
installation
Junction box
location for:
wall installation
All models
Voltage Max. current Max.
draw load
208V 16.6 A 3.5 kW
240V
19.4 A 4.6 kW
1
Disconnect the power supply.
2
Remove the junction box cover.
3
Connect the oven cable to the junction
box through the U.L.-listed conduit
connector.
4
Connect the two black wires together
with twist-on connectors.
5
Connect the two red wires together with
twist-on connectors.
6
Connect electrical connection according
to local codes and ordinances.
If local codes permit connecting the
cabinet-grounding conductor to the neutral
white wire in the junction box:
7A
Connect the factory-taped green and white
oven cable wires to the neutral (white) wire
in the junction box.
8A
Replace the junction box cover.
OR If local codes DO NOT PERMIT
connecting the cabinet-grounding
conductor to the neutral (white) wire in
junction box:
7B
Separate the factory-taped green and
white oven cable wires.
8B
Connect the white oven cable wire to
the neutral (white) wire in junction box.
9B
Connect the green grounding oven cable
wire to a grounded wire in the junction
box.
!0B
Replace the junction box cover.
OR If connecting to a four-wire electrical
system:
7C
Separate the green and white oven cable
wires.
8C
Connect the white oven cable wire to the
neutral (white) wire in junction box.
9C
Connect the green grounding oven cable
wire to the (green) grounding wire in the
junction box.
Do not connect the green grounding wire to
the neutral (white) wire in junction box.
!0C
Replace the junction box cover.
Nameplate
cable from
power supply
black
wires
UL - listed
conduit
box
red wires
white and green
grounding oven
wires - factory
taped
UL - listed
conduit connector
box
cable from
power supply
white
wires
red wires
green grounding
oven wires
- factory taped
black
wires
Summary of Contents for OB24SC
Page 1: ...INSTALLATION GUIDE US CA 591362A 11 17 BUILT IN OVEN OB24SC models ...
Page 9: ...8 ...
Page 10: ...9 ...
Page 11: ...10 ...
Page 12: ...GUIDE D INSTALLATION CA 591362A 11 17 FOUR ENCASTRÉ Modèles OB24SC ...
Page 20: ...19 ...