- 4 -
NOTE. There is still power to the components
when the POWER button in the “off” state.
Always unplug the power cord before
commencing service work or disassembly.
2.
To remove the lid, open it to the upright
position and lift it clear.
3.
Remove 2 screws from the rear of the
console. The console can be removed to gain
access to the Motor Controller Module, Display
Module and wiring.
NOTE: Modules removed from the machine for
return must be protected from electrostatic damage
while in transit by using the special
package in
which the spare parts were received.
Removing Top Deck
4.
Disconnect Display Module, Motor/Pump,
Rotor Position Sensor harnesses, pressure tube
and diverter valve wiring assembly. Unclamp
Power Cord by removing the 2 screws holding the
cord clamp and remove ground wire and power
cord plug through the clamp opening.
5.
Remove two rubber buffers and screws from
the front of the top deck.
Removing the Basket
6.
Unclip the bias spring from the front left
suspension rod. Unclip the neck ring from the top
of the tub.
7.
Remove the fabric softener dispenser,
unscrew the agitator retaining nut and remove the
agitator.
8.
The basket may now be lifted clear. If the
basket is not easy to lift clear, then remove the
three-spline retaining screws and remove the
driven spline off the shaft and lift out.
Diverter Valve
9.
If the valve is replaced, ensure that a hose
clip is refitted to secure the hose to the tub.
Specifications are subject to change without notice.
After Reassembly and Testing…
If the machine is advanced to either rinse or spin
whilst filling or re-circulating, it may take up to 3
minutes before the drain pump turns on. This time
allows the diverter valve to cool down and direct
the water flow to the drain hose.
If further help is needed
concerning this appliance
in USA or Canada call:
TOLL FREE 1 888 9 FNP USA
(1 888 936 7872)
Or write to:
Fisher & Paykel Appliances Inc.
27 Hubble
Irvine, CA 92618
P/N 420600