16
|
COFFEE MAKER INSTALLATION GUIDE
Verify the minimum measurements required for correct installation of the appliance. The coffee maker must be
installed in a column and the column must be firmly fixed to the wall with commercially available brackets.
IMPORTANT!
●
All installation or maintenance operations must be performed with the appliance disconnected
from the mains electricity supply.
●
Kitchen furniture in direct contact with the appliance must be heat resistant 149°F min (65°C min).
●
To guarantee correct ventilation, leave a gap at the bottom of the cabinet
(see measurements below).
6A
CABINETRY DIMENSIONS (18 1/8" (460mm) HIGH CAVITY)
PROUD INSTALL
FLUSH INSTALL
5/8–13/16"
(16–20mm)
min 1/16" (2mm)
5/8–13/16"
(16–20mm)
Electrical supply
CABINETRY DIMENSIONS
EB24 MODELS
inches (mm)
I
Minimum inside width of cavity
22 1/16" (560)
J
Overall width of cabinetry
23 5/8" (600)
K
Minimum inside height of cavity
17 3/4" (450)
L
Overall height of cabinetry
18 1/8" (460)
M
Minimum inside depth of cavity
21 7/16" (545)
n
Ventilation Air Gap
2" (50)
TOP
SIDE
M
J
I
L
k
n
13/16"
(20mm)
13/16"
(20mm)
Summary of Contents for EB24
Page 3: ...WARMING DRAWER WB24 models ...
Page 14: ...COFFEE MAKER EB24 models 12 95 20 25 560 00 00 00 ...
Page 23: ...STEAM OVEN OS24N models 5 22 00 556 00 565 30 42 00 ...
Page 31: ...SPEED OVEN OM24N models 35 22 00 556 00 565 30 42 00 ...
Page 41: ...TIROIR CHAUFFANT Modèles WB24 ...
Page 52: ...MACHINE À CAFÉ Modèles EB24 12 95 20 25 560 00 00 00 ...
Page 60: ...FOUR À VAPEUR Modèles OS24N 5 22 00 556 00 565 30 42 00 ...
Page 68: ...FOUR À MICRO ONDES Modèles OM24N 35 22 00 556 00 565 30 42 00 ...