6 FAULT
FINDING
6.1 Fault
Finding
Fault Cause
Repair
•
No operation.
•
No power to unit.
•
No power at terminal C on
timer.
•
Hi-limit thermostat open circuit
(electric only).
•
Start button not operating.
•
Idler switch open circuit.
•
Motor seized or open circuit.
•
Door switch open circuit.
•
Resupply power to the unit.
•
Replace timer.
•
Replace hi- limit thermostat &
check for possible overheating
issues (see overheating).
•
Replace selector switch
assembly.
•
Check belt condition & replace if
necessary.
Check idler arm or pulley &
replace if necessary.
Check idler switch operation and
replace if necessary.
•
Check motor spins freely and
check windings. Replace if
necessary.
•
Replace door switch.
•
No heat.
•
Selector set on No Heat/Fluff.
•
No power to terminal A on the
timer.
•
No motor operation.
•
No Power from Terminal 16
on the selector.
•
The safety, inlet, or drum
outlet thermostat failure.
•
The elements are open circuit
(electric model only).
•
No gas valve operation (gas
model only).
•
Open circuit motor switch.
•
Reset selector.
•
Replace the timer.
•
See No Operation section.
•
Replace the selector.
•
Check thermostats for continuity
and resistance of the resistors.
Replace if necessary.
•
Replace elements.
•
Check flame failure operation.
Check gas coil continuity.
Change gas valve assembly.
•
Replace the motor.
Summary of Contents for DE09
Page 1: ...479536 Service Manual Dryers Models DE09 DG09 DE60FA DG60FA ...
Page 4: ...479536 4 9 3 Electric Selector Sequence 49 9 4 Gas Selector Sequence 50 ...
Page 6: ...479536 6 2 INSTALLATION 2 1 Electric Model Installation ...
Page 7: ...479536 7 ...
Page 8: ...479536 8 ...
Page 9: ...479536 9 ...
Page 10: ...479536 10 ...
Page 11: ...479536 11 2 2 Gas Model Installation ...
Page 12: ...479536 12 ...
Page 13: ...479536 13 ...
Page 14: ...479536 14 ...
Page 15: ...479536 15 ...
Page 16: ...479536 16 ...
Page 19: ...479536 19 4 COMPONENT SERVICING 4 1 Top Disassembly ...
Page 40: ...479536 40 No Heat Fluff Normal Heat Cotton Regular ...
Page 45: ...479536 45 7 FLOW CHARTS 7 1 Electric Flow Chart ...
Page 46: ...479536 46 7 2 Gas Flow Chart ...
Page 47: ...479536 47 8 WIRING DIAGRAMS 8 1 Electric Wiring Diagram ...
Page 48: ...479536 48 8 2 Gas Wiring Diagram ...
Page 50: ...479536 50 9 4 Gas Selector Sequence ...
Page 51: ...479536 51 ...