11

7b

7c

ø 60 mm

ø 60 mm

max. 5 mm

max. 5 mm

220 mm

220 mm

100 mm

100 mm

ø60mm

Services can be located 
either side of dishwasher

VENT HOSE

VENT HOSE

& SERVICES

SERVICES

Services can be located 
either side of dishwasher

Shelf cutouts

Shelf cutouts

The ø60 mm services hole should 
be enlarged to accomodate the 
extra venting hose by 
cutting out some material from 
the bottom corner. 

External Venting kit (1)

External Venting kit (1)

INTEGRATED MODELS WITH REMOTE ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET

INTEGRATED MODELS WITH REMOTE ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH ADJACENT CABINET

min. 100 mm

min.100 mm

Important!

To prevent  pooling of condensation from the vent hose, a 
toekick height of no less than 100 mm is required.

Important!

To prevent  pooling of condensation from the vent hose, a 
toekick height of no less than 100 mm is required.

Summary of Contents for DD60SCB7

Page 1: ...NZ AU GB IE 590200D 04 13 DD60S 7 DD60ST 7 models INSTALLATION INSTRUCTIONS DishDrawerTM dishwasher ...

Page 2: ...ECURE BY DRAWER REMOVAL CHOOSE DRAINAGE OPTION FINAL CHECKLIST CONNECTTOWATER ELECTRICITY CHOOSE DRAINAGE OPTION TROUBLESHOOTING PARTS SUPPLIED CAVITY PREPARATION EXTERNAL VENTING MAXIMUM DISTANCE OF HOSES CORD FROM CHASSIS EDGE FOLLOW STEPS FOR THE EXTERNAL VENTING KIT INSTALL THE FRONT PANEL INSTALL THE FRONT PANEL CONNECTTOWATER ELECTRICITY CONNECTTOWATER ELECTRICITY CHOOSE DRAINAGE OPTION CONN...

Page 3: ...e enclosure if service is required The switched power outlet must be outside the dishwasher cavity so that it is accessible after installation Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord and hoses If the dishwasher is to be relocated from one installation to another it must be kept upright to avoid damage from water sp...

Page 4: ...gh our local website listed at the end of this document Clamp 1 for securing Drain hose joiner Wire clip 1 for securing Drain hose joiner Phillips 16 mm screws 7 38 mm bottom fixing screws metal washers 2 Drain hose support 1 Moisture protection tape 1 to prevent moisture damage Cavity bracket kit 1 supplied with Tall height Designer and Integrated models only Drain hose joiner 1 Rubber washer for...

Page 5: ...D MODELS 3b External Venting kit 1 supplied with Integrated models with remote only Panel mounting screws 6 Panel bracket 1 attached to product Integrated rectangular badge 1 Satin chrome supplied supplied with Integrated models with badge only ...

Page 6: ...of chassis to back of front panel 553 553 553 553 553 553 553 553 553 553 E maximum extension of drawer excl handle 556 545 5453 5453 556 545 5453 5453 5453 5453 F depth of front panel excl handle 29 18 16 20 16 20 29 18 16 20 16 20 16 20 16 20 G height1 of chassis 410 410 410 410 454 454 454 454 454 454 H depth of handle n a 41 n a n a n a 41 n a n a n a n a I height of front panel 394 398 4084 m...

Page 7: ...stom drawer front panel will also be different for these two options Cabinetry dimensions mm STANDARD HEIGHT MODELS TALL HEIGHT MODELS Classic Designer Integrated Remote control Integrated Badge control Classic Designer Integrated Remote control 456 mm cavity Integrated Badge control 456 mm cavity Integrated Remote control 480 mm cavity Integrated Badge control 480 mm cavity L inside height of cav...

Page 8: ...cabinet front min 2 mm ventilation gap min 2 mm WIDTH OF PANEL min 596 mm HEIGHT OF PANEL 2x FRONT PANEL SPECIFICATIONS 16 20 mm panel thickness Maximum weight of panel 9 kg Adequately sealed to withstand moisture 50O C 80 RH Because of it being a hot and wet environment generally the back and sides of the panel should be completely sealed with a waterproof vapour barrier ie polyurethane to preven...

Page 9: ...gap min 8 mm WIDTH OF PANEL min 596 mm HEIGHT OF PANEL 2x FRONT PANEL SPECIFICATIONS 16 20 mm panel thickness Maximum weight of panel 9 kg Adequately sealed to withstand moisture 50O C 80 RH Because of it being a hot and wet environment generally the back and sides of the panel should be completely sealed with a waterproof vapour barrier ie polyurethane to prevent damage to the panel The back of t...

Page 10: ...145 psi Min 0 03 MPa 4 3 psi Important Adjacent cabinetry must not extend above cavity base Important The power outlet must be located in a cabinet adjacent to the dishwasher cavity 220 240 VAC min 4 8 A min ø 60 mm min 200 mm Moisture protection tape must be applied Services can be located either side of the dishwasher These marks indicate formed bracket screw locations if securing by drawer remo...

Page 11: ...out some material from the bottom corner External Venting kit 1 External Venting kit 1 INTEGRATED MODELS WITH REMOTE ONLY PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET INTEGRATED MODELS WITH REMOTE ONLY PREPARATION FOR EXTERNAL VENTING THROUGH ADJACENT CABINET min 100 mm min 100 mm Important To prevent pooling of condensation from the vent hose a toekick height of no less than 100 mm is re...

Page 12: ...eless models only Venting hose 1925 mm Power cord excl plug 1650 mm Drain hose 1800 mm Inlet hose 1250 mm Power cord excl plug 1650 mm Drain hose 2000 mm Drain hose 1800 mm Inlet hose 1650 mm Inlet hose 1250 mm Venting hose 1525 mm Venting hose 1925 mm Integrated models with remote NZ AU only Integrated models with remote NZ AU only Power cord excl plug 1650 mm Power cord excl plug 1650 mm ...

Page 13: ...ty left after installation 2 1 Ensure the cavity panel bracket is positioned so that the F arrow is pointing towards the front of the chassis Firmly push the bracket so that the prongs engage with the top tabs and it clicks into place Ensure the top trim seal is facing forward after attaching the bracket Important Ensuretheprongshavenotbeen drivendownintothechassisas thiswilldamagethelidbelow 1 2 ...

Page 14: ...g product into cavity The mounting slots are in pairs one on each side diagonally across the product A bracket must match A slot and B bracket must match B slot Check that the fitted elbow is rotated left or right depending on the direction of the routing then ensure the venting hose is securely attached to it NOW CHOOSE WHICH INSTALLATION METHOD a or b IS MORE SUITABLE FOR YOUR CABINETRY B B B A ...

Page 15: ... the drawer halfway Using a flat bladed screwdriver prise the grey rubber plug out of the trim moulding Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward Repeat for all four brackets Using a small Philips screwdriver screw through the trim moulding securing the side mounting bracket to the cabinetry Do not damage the rubber trimseal 14a 2 1 After r...

Page 16: ... cabinet as per step 7b or 7c ALTERNATIVE METHOD b SECURE BY DRAWER REMOVAL INTEGRATED MODELS WITH REMOTE ONLY ATTACH VENTING HOSE As you push product in pull through hoses and cord ensuring they don t get kinked or twisted Important If product cannot be pushed in far enough pull out again and rearrange hoses and cord Do not use excessive force as doing so may squash the hoses and lead to incorrec...

Page 17: ...removal Press the release tabs in on either side and push back to release drawer from runners Push drawer runners back in Product may move Mark chassis position on cavity 1 2 The product has three pairs of fixing points Ensure the sound insulation is repositioned correctly a pair of fixing holes either side on the bottom use 38 mm fixing screws washers two pairs of formed brackets on either side o...

Page 18: ...REMOTE ONLY INSTALLING THE FRONT PANEL 1 1 2 3 Electrical Shock Hazard Before continuing ensure that the product is disconnected from the power supply Failure to follow this warning may result in electrical shock injury or fire WARNING EARTH THE PANEL WARNING WARNING To earth the panel bracket connect the earth wire from the product to one of the tabs Any custom metal component e g handle that ext...

Page 19: ...to the hole above the door pin and rotate the panel up or down to align the gaps in your cabinetry Repeat on the other side if necessary The panel has a maximum travel of 2 mm up or down Important Ensurethatyoumaintainaminimumof2mmventilation gapbelowthepanel or 2 mm 20a INTEGRATED MODELS WITH REMOTE ONLY INSTALLING THE FRONT PANEL ...

Page 20: ...used each side Align bottom of panel with bottom of bracket 228 5 mm 228 5 mm 127 mm 255 mm 30 mm 25 mm 1 3 4 1 2 1 2 Badge zone INTEGRATED MODELS WITH BADGE ONLY INSTALLING THE FRONT PANEL BADGE CONTROLS Electrical Shock Hazard Before continuing ensure that the product is disconnected from the power supply Failure to follow this warning may result in electrical shock injury or fire WARNING ...

Page 21: ...Ensuretherubberseal betweenthedrawer andpanelsiskeptin place When refitting the door pins ensure they are orientated as shown Push the panel in then up to locate INTEGRATED MODELS WITH BADGE ONLY INSTALLING THE FRONT PANEL BADGE CONTROLS REATTACH BADGE EARTH THE PANEL 1 2 WARNING Electrical Shock Hazard Connect the integrated badge earth wire to one of the two tabs provided on the panel bracket To...

Page 22: ...ner 750 882 5 mm 750 882 5 mm min R 200 mm min R 200 mm Supplied drain hose joiner 19 mm waste tee HIGHLOOP min 150 mm Ensure drain hose is routed straight to joiner Remove excess drain hose material if necessary Do not shorten the inlet hose Dishwasher and Standpipe Ø 38 mm Ensure the supplied rubber washer is fitted inside the coupling Tighten coupling with spanner 180o No leaks CONNECT INLET HO...

Page 23: ...waste connection highloop not properly installed drain hose not routed correctly or spray arm not in place No water supply This is displayed as a U1 fault see section If there is a fault in the User guide for how to recognise this fault on models without a display Check water is connected and turned on The dishwasher is beeping continuously There is a fault See section If there is a fault in the U...