SAFETY AND WARNINGS - ALL MODELS

ADDITIONAL SAFETY AND WARNINGS - INTEGRATED MODELS ONLY

2a

2b

 

WARNING!

 

Electrical shock hazard

 

   

 

Before installing the dishwasher, remove the house fuse or open the circuit 
breaker.

This appliance must be earthed. In the event of a malfunction or breakdown, 
earthing will reduce the risk of electric shock by providing a path of least 
resistance for electric current. This appliance is equipped with a cord having an 
equipment-earthing conductor and an earthing plug. The plug must be plugged 
into an appropriate outlet that is installed and earthed in accordance with all 
local codes and ordinances. WARNING- Improper connection of the equipment-
earthing conductor can result in a risk of electric shock. Check with a qualified 
electrician or service representative if you are in doubt as to whether the 
appliance is properly earthed.

Do not modify the power supply plug provided with the appliance - if it will not 
fit the outlet, have a proper outlet installed by a qualified electrician. Do not use 
an extension cord, adapter plug or multiple outlet box.

 

Failure to follow this advice may result in electrical shock or death.

 

WARNING!

 

Cut hazard

 

   

 

Take care - panel edges are sharp.

 

Failure to use caution could result in injury or cuts.

 

IMPORTANT SAFETY INSTRUCTIONS! 

 

Installation of this dishwasher requires basic mechanical and electrical skills.

 

Be sure to leave these Instructions with the Customer.

 

Installation must comply with your local building and electricity regulations.

 

At the completion of the dishwasher installation, the Installer must perform the Final Checklist.

 

Remove all packaging materials supplied with the dishwasher.

 

This dishwasher is manufactured for indoor use only.

 

Ensure all water connections are turned OFF. It is the responsibility of the plumber and 

 

electrician to ensure that each installation complies with all Codes and Regulations.

 

The dishwasher MUST be installed to allow for future removal from the enclosure if service is required.

 

The switched power outlet must be outside the dishwasher cavity, so that it is accessible after 

 installation.

 

Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to 
the power supply cord and hoses.

 

If the dishwasher is to be relocated from one installation to another it must be kept upright to avoid 
damage from water spillage.

 

Make sure only new hoses are used for connection (supplied with the dishwasher). Old hoses should 
not be reused.

 

Failure to install the dishwasher correctly could invalidate any warranty or liability claims.

 

If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle, 
boat or mobile facility containing the product to the service shop at your expense or pay the service 
technician’s travel to the location of the product.

 

SAVE THESE INSTRUCTIONS

 

IMPORTANT SAFETY INSTRUCTIONS! 

 

 

Read these instructions completely and carefully.

 

Ensure the product is not plugged in.

 

Installation of custom panels requires basic mechanical and electrical skills.

 

Installation must comply with your local building and electricity regulations.

 

Failure to install the custom panels correctly could invalidate any warranty or liability claims.

 

SAVE THESE INSTRUCTIONS

 

 

           

Electrical Shock Hazard

WARNING: To reduce the risk of electrical shock, fire, or injury to persons, the 
installer must ensure that the dishwasher is completely enclosed at the time 
of installation.
Before fitting the front panels and connecting the integrated badges (where 
present), the installer must ensure that the dishwasher is disconnected from 
the power supply.
After installing the front panels, the installer must ensure that the following 
components are electrically earthed: the panel bracket, the integrated badge 
(where present) and any custom metal component (e.g. handle) that extends 
past the rubber seal.

Failure to follow these warnings may result in electrical shock, injury or fire.

 WARNING!

   

Fitting integrated front panels requires access to electrical service areas. 
This work must be performed and certified by a qualified electrical service technician.

Summary of Contents for DD60D 7

Page 1: ...NZ AU GB IE 590200D 04 13 DD60D 7 models INSTALLATION INSTRUCTIONS DishDrawerTM dishwasher...

Page 2: ...SECURE BY DRAWER REMOVAL TROUBLESHOOTING Designer DD60DI7 PRODUCT CABINETRY DIMENSIONS CUSTOM PANEL CALCULATIONS PARTS SUPPLIED CHOOSE DRAINAGE OPTION FINAL CHECKLIST CONNECTTOWATER ELECTRICITY CAVIT...

Page 3: ...enclosure if service is required The switched power outlet must be outside the dishwasher cavity so that it is accessible after installation Care should be taken when the appliance is installed or rem...

Page 4: ...Centre or our local website listed at the end of this document Clamp 1 for securing Drain hose joiner Wire clip 2 for securing Drain hose joiner Phillips 16 mm screws 9 Drain hose support 1 Moisture...

Page 5: ...mounting screws 12 Toekick mounting screws 5 Toekick mounting bracket 1 A custom toekick panel of any material with thickness 9 19 mm can be screwed to the plastic toekick mounting bracket Integrated...

Page 6: ...ht of levelling feet 9 692 9 692 9 692 9 692 I depth of handle n a 41 n a n a J depth of toekick recess to back of front panel 4 30 50 30 50 30 845 30 845 K height of upper front panel 394 398 min 398...

Page 7: ...s mm Classic Designer Integrated Remote control Integrated Badge controls P inside height of cavity min 820 min 820 min 820 min 820 Q inside width of cavity 600 600 600 600 R inside depth of cavity mi...

Page 8: ...8 mm height from top of product to toekick panel mounting point clearance to floor min 12 mm upper panel extension 0 mm recommended upper panel extension 0 mm recommended min 717 mm B minimum height W...

Page 9: ...lations Water Pressure Water softener models Max 1 MPa 145 psi Min 0 1 MPa 14 5 psi Models without water softener Max 1 MPa 145 psi Min 0 03 MPa 4 3 psi Important The power outlet must be located in a...

Page 10: ...UM DISTANCE OF HOSES CORD FROM CHASSIS EDGE Drain hoses 1800 mm Inlet hose 1250 mm Power cord excl plug 1650 mm Drain hoses 2000 mm Inlet hose 1650 mm Power cord excl plug 1650 mm Left hand side Right...

Page 11: ...bladed screwdriver Ensure they re securely fitted before sliding product into cavity The mounting slots are in pairs one on each side diagonally across the product A bracket must match A slot and B b...

Page 12: ...ther side Mounting rail Score along with a knife Turn the toekick over and score along the same line Gently snap off the excess 11a SECURE TO THE CABINETRY ON THE SIDES 1 3 2 Open the drawer halfway U...

Page 13: ...ners Push drawer runners back in 9b PULL THROUGH HOSES PUSH INTO THE CAVITY optionally attach the two top mounting brackets You can initially level the product You can raise or lower the product by tw...

Page 14: ...ter securing ensure the sound insulation is repositioned correctly Secure using two pairs of formed brackets Repeat on the other side of the chassis 12b OPTIONALLY SECURE TO THE CABINETRY ABOVE x2 The...

Page 15: ...oint on the toekick with a pencil Lay the toekick face down on a chopping board or similiar Smooth the edge with a file Be careful of sharp edges Snap off the two end tabs Slide the toekick onto the m...

Page 16: ...keptin place Repeatfortheotherdrawer Repeatfortheotherdrawer Electrical Shock Hazard Before continuing ensure that the product is disconnected from the power supply Failure to follow this warning may...

Page 17: ...anel onto the supplied panel With the front panels fitted insert an appropriately sized Philips screwdriver into the hole above the door pin and rotate the panels up or down to align the gaps in your...

Page 18: ...screws used each side Align bottom of panels with bottom of brackets 1 3 4 1 2 1 2 Badge zone 228 5 mm 228 5 mm 127 mm 211 mm 54 mm 127 mm 30 mm 25 mm dge zone Repeatfortheotherdrawer Repeatfortheothe...

Page 19: ...Important Ensurethatyoumaintainaminimum of8mmventilationgapbetweenthe upperandlowerpanels or 2 mm 1 2 Important Ensuretherubberseal betweenthedrawer andpanelsiskeptin place When refitting the door pi...

Page 20: ...882 5 mm 750 882 5 mm min R 200 mm min R 200 mm Supplied drain hose joiner 19 mm waste tee Ensure drain hose is routed straight to joiner Remove excess drain hose material if necessary Do not shorten...

Page 21: ...n hose blocked waste connection highloop not properly installed drain hose not routed correctly or spray arms not in place No water supply This is displayed as a U1 fault see section If there is a fau...