Fisher & Paykel DD24DV2T9 Installation Manual Download Page 21

1

IMPORTANT!  

 

SAVE THESE INSTRUCTIONS

The models shown in this installation guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our 
website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.

  IMPORTANT SAFETY INSTRUCTIONS

 

Installation of this dishwasher requires basic mechanical and electrical skills.

 

Be sure to leave these Instructions with the Customer.

 

Installation must comply with your local building, electricity, and plumbing regulations.

 

At the completion of the dishwasher installation, the Installer must perform the Final 
Checklist.

 

Remove all packaging materials supplied with the dishwasher.

 

This dishwasher is manufactured for indoor use only.

 

Ensure all water connections are turned OFF. It is the responsibility of the plumber and 
electrician to ensure that each installation complies with all Codes and Regulations.

 

The dishwasher MUST be installed to allow for future removal from the enclosure if 
service is required.

 

The switched power outlet must be outside the dishwasher cavity, so that it is accessible 
after installation.

 

Care should be taken when the appliance is installed or removed to reduce the likelihood 
of damage to the power supply cord and hoses.

 

If the dishwasher is to be relocated from one installation to another it must be kept 
upright to avoid damage from water spillage.

 

Make sure only new hoses are used for connection (supplied with the dishwasher). Old 
hoses should not be reused.

 

Failure to install the dishwasher correctly could invalidate any warranty or liability claims.

 

If the product is installed in a motor vehicle, boat or similar mobile facility, you must 
bring the vehicle, boat or mobile facility containing the product to the service shop at 
your expense or pay the service technician’s travel to the location of the product.

 

This dishdrawer is intended for connection to the hot-water supply.

 WARNING!

Electrical Shock Hazard
Before installing the dishwasher, remove the house fuse or open the circuit
breaker. If permanently connecting the dishwasher, be sure the power is 
isolated and the dishwasher unplugged.

GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of a malfunction or breakdown,
grounding will reduce the risk of electric shock by providing a path of least
resistance for electric current. This appliance is equipped with a cord having
an equipment-grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is installed and grounded in 
accordance with all local codes and ordinances. WARNING - Improper 
connection of the equipment-grounding conductor can result in a risk of 
electric shock. Check with a qualified electrician or service representative if 
you are in doubt as to whether the appliance is properly grounded.

If the dishwasher is installed as a permanently connected appliance:
GROUNDING INSTRUCTIONS - This appliance must be connected to a 
grounded metal, permanent wiring system, or an equipment-grounding 
conductor must be run with the circuit conductors and connected to the 
equipment-grounding terminal or lead on the appliance.
Do not modify the power supply plug provided with the appliance - if it will 
not fit the outlet, have a proper outlet installed by a qualified electrician. Do 
not use an extension cord, adapter plug or multiple outlet box.
Failure to follow this advice may result in electrical shock or death.

 WARNING!

Cut Hazard
Take care - panel edges are sharp.
Failure to use caution could result in injury or cuts.

!

!

1

   SAFETY AND WARNINGS

Summary of Contents for DD24DV2T9

Page 1: ...591385 B 07 18 INSTALLATION GUIDE US CA DOUBLE DISHDRAWERTM DISHWASHER DD24DDFT DD24DV2T models...

Page 2: ...ilar mobile facility you must bring the vehicle boat or mobile facility containing the product to the service shop at your expense or pay the service technician s travel to the location of the product...

Page 3: ...er Wire clip 2 for securing Drain hose joiner Phillips 5 8 16 mm screws 9 Drain hose support 1 Moisture protection tape 1 to prevent moisture damage to cabinetry Drain hose joiner 1 Top mounting brack...

Page 4: ...ide the terminal block cover sideways to unlock and hinge open to access the terminal block 6 Unscrew the Live Neutral and Earth wires as shown 7 Unscrew the three screws on the base as shown and remo...

Page 5: ...d through or under under housing ribs 9 Screw down the Live Neutral and Earth wires correctly 10 Push the plastic harness cover back over It should clip back into place 11 Fold down and slide back the...

Page 6: ...855 33 11 16 855 G Height of drawer front panels 30 762 30 762 H Height of upper drawer front panel 17 3 8 442 17 3 8 442 I Height of lower drawer front panel 12 1 4 312 12 1 4 312 J Height from top o...

Page 7: ...in 34 864 min 34 864 Q Inside width of cavity 23 5 8 600 24 610 R Inside depth of cavity min 22 1 16 560 min 22 1 16 560 S Recommended height of adjacent cabinet space 30 762 30 762 T Height of toekic...

Page 8: ...120 VAC max 15 A max 1 1 2 38 mm max 17 11 16 450 mm min 7 7 8 200 mm Moisture protection tape must be applied Services hole Can be located either side of dishwasher preferably at the bottom of the ca...

Page 9: ...OSES CORD FROM CHASSIS EDGE LEFT HAND SIDE RIGHT HAND SIDE Drain hoses 78 1 2 2000mm Drain hoses 70 1 2 1800mm Inlet hose 64 3 4 1650mm Inlet hose 49 1250mm Power cord excl plug 29 1 2 750mm Power cor...

Page 10: ...flat bladed screwdriver Ensure they re securely fitted before sliding product into cavity The mounting slots are in pairs one on each side diagonally across the product A bracket must match A slot and...

Page 11: ...ewdriver prise the grey rubber plug out of the trim moulding Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward Repeat for all four brackets Using a sm...

Page 12: ...8 B PULL THROUGH HOSES PUSH INTO THE CAVITY 9 B REMOVE THE LOWER DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side recommended or rotate the drawer clockwise resting it o...

Page 13: ...Ensure product is level and aligning with cabinetry Hexagonal socket The top mounting brackets will only bend upwards a maximum of 10 mm 2 B REFIT THE DRAWER ONTO THE RUNNERS Before refitting the dra...

Page 14: ...pencil Lay the toekick face down on a chopping board or similiar Smooth the edges with a file Be careful of sharp edges Snap off the two end tabs Slide the toekick onto the mounting rails either side...

Page 15: ...IMPORTANT Ensure that drain connection will comply with local plumbing regulations min R 8 200 mm 29 1 2 34 3 4 750 882 5 mm 1 1 2 38 mm 29 1 2 34 3 4 750 883 mm Screw Drain hose support to back wall...

Page 16: ...al Double Air Gap Break Kit This provides totally separate draining for each drawer and eliminates possible cross draining problems DRAINAGE OPTION 2 Dishwasher using Dual Air Gap Break with Drain Hos...

Page 17: ...883 mm step 15 Supplied drain hose joiner to suit 3 4 19 mm waste tee Ensure drain hose is routed straight to joiner Remove excess drain hose material if necessary Do not shorten the inlet hose 29 1...

Page 18: ...ed on If it is and still no indicator ligths up see the Preference options section of the Quick start guide An option called Open drawer auto power on may need to be turned on Water around water suppl...

Page 19: ...igher than the drain hose joiner Ensure any packaging or tape securing the racks is removed from the drawers Water softener models only adjust the water softener setting from the default setting to su...

Page 20: ...591385 B 07 18 INSTALLATION GUIDE US CA SINGLE DISHDRAWERTM DISHWASHER DD24SDFT DD24SV2T models...

Page 21: ...ilar mobile facility you must bring the vehicle boat or mobile facility containing the product to the service shop at your expense or pay the service technician s travel to the location of the product...

Page 22: ...2 OPTIONAL Rubber washer for inlet hose 1 comes already fitted Side mounting bracket kit A and B 2 OPTIONAL Edge Protector 1 If the services hole is through a metal partition the hole must be protecte...

Page 23: ...Slide the terminal block cover sideways to unlock and hinge open to access the terminal block 6 Unscrew the Live Neutral and Earth wires as shown 7 Unscrew the three screws on the base as shown and re...

Page 24: ...ed through or under under housing ribs 9 Screw down the Live Neutral and Earth wires correctly 10 Push the plastic harness cover back over It should clip back into place 11 Fold down and slide back th...

Page 25: ...chassis to back of front drawer panel 21 3 4 553 21 3 4 553 E Depth of drawer front panel excl handle 13 16 20 13 16 20 F Height of drawer front panel 18 1 2 470 17 3 8 442 G Height of chassis1 17 7...

Page 26: ...slots m l K PROFILE PLAN DD24SDFT DD24SV2T CABINETRY DIMENSIONS INCHES MM INCHES MM K Inside height of cavity 18 7 8 480 17 15 16 456 L Inside width of cavity 23 5 8 600 24 610 min 1 2 13 mm clearanc...

Page 27: ...cabinetry must not extend above cavity base These marks indicate formed bracket screw locations if securing by drawer removal If there is no side partition you can construct timber bracing as somethi...

Page 28: ...oned so that the F arrow is pointing towards the front of the chassis Firmly push the bracket so that the prongs engage with the top tabs and it clicks into place Ensure the top trim seal is facing fo...

Page 29: ...o not use excessive force as doing so may squash the hoses and lead to incorrect operation A A A B B Clip all four side mounting brackets into their slots using a flat bladed screwdriver Ensure they r...

Page 30: ...y rubber plug out of the trim moulding Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward Repeat for all four brackets Using a small Philips screwdrive...

Page 31: ...r side and push back to release drawer from runners Lift drawer off runners Push drawer runners back in on either side Push drawer runners back in on either side Sit the drawer down Rotate the drawer...

Page 32: ...clockwise the drawer back onto the drawer runners on either side Pull the release tabs forward on both sides 4 100mm Ensure the tabs are fully pulled forward and click into place Release tab The produ...

Page 33: ...e IMPORTANT Ensure that drain connection will comply with local plumbing regulations min R 8 200mm 29 1 2 34 3 4 750 882 5 mm 1 1 2 38 mm 29 1 2 34 3 4 750 883mm Screw Drain hose support to back wall...

Page 34: ...l comply with local plumbing regulations DRAINAGE OPTION 2 Dishwasher using Air Gap Break with Drain Hose Joiner 37 3 8 950mm Max height to top of Air Gap Break countertop or wall mounted step 14 Secu...

Page 35: ...50 883mm step 14 Supplied drain hose joiner to suit 3 4 19 mm waste tee Ensure drain hose is routed straight to joiner Remove excess drain hose material if necessary Do not shorten the inlet hose 29 1...

Page 36: ...16 Ensure the supplied rubber washer is fitted inside the coupling Tighten coupling with spanner 180o No leaks 1 2 4 CONNECT INLET HOSE TO HOT WATER 5 SWITCH PRODUCT ON...

Page 37: ...r is opened Ensure power is connected and is switched on If it is and still no indicator lights up see the Preference options section of the Quick start guide An option called Open drawer auto power o...

Page 38: ...s a minimum 150 mm higher than the drain hose joiner Ensure any packaging or tape securing the racks is removed from the drawers Water softener models only adjust the water softener setting from the d...

Page 39: ...19...