Fisher & Paykel DD24DCT Installation Manual Download Page 18

17

Ensure the supplied 
rubber washer is 
fitted inside the 
coupling.

Tighten coupling 
with spanner.

180

o

No leaks!

1

2

!8

 

TROUBLESHOOTING

 

Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an 

A3

 fault)

Check for a kinked drain hose, blocked waste connection, highloop not properly installed, drain hose not routed correctly or spray arms not in place.

 

No water supply. (This is displayed as an 

A1

 fault 

Check water is connected and turned on.

 

The dishwasher is beeping continuously

There is a fault. See section ‘If there is a fault’ in the User guide for further information and instructions.

 

No program indicator lights up when the drawer is opened

Ensure power is connected and is switched on. If it is and still no indicator ligths up, see the ‘Preference options’ section of the ‘Quick start guide’. 
An option called ‘Open drawer auto power-on’ may need to be turned on.

 

Water around water supply and drainage connections

 

Check connections, existing plumbing and hoses for leaks. Check rubber washer and hose clamp are correctly fitted.

 

If product is tipping

Ensure the product is secured to the cabinetry. 

 

If front panels are misaligned

Check and relevel product. Check the cabinetry is square. For Integrated models, check and adjust front panel alignment if necessary.

 

Drawer doesn’t close properly

Ensure nothing is obstructing the drawer from closing properly eg hoses or drawer latches.

 

If a problem occurs, consult the ‘Troubleshooting’ section of the User guide.

 

If after checking these points you still need assistance, please refer to the Service & Warranty book for warranty details and your nearest Authorized Service Center, or contact us through our 
website, listed below.

!6

   CONNECT INLET HOSE TO HOT WATER

!7

   SWITCH PRODUCT ON

Summary of Contents for DD24DCT

Page 1: ...591153B 08 17 INSTALLATION GUIDE US CA DD24DA DD24DCT models DOUBLE DISHDRAWERTM DISHWASHER ...

Page 2: ...milar mobile facility you must bring the vehicle boat or mobile facility containing the product to the service shop at your expense or pay the service technician s travel to the location of the product This dishdrawer is intended for connection to the hot water supply WARNING Electrical Shock Hazard Before installing the dishwasher remove the house fuse or open the circuit breaker If permanently c...

Page 3: ...ner Wire clip 2 for securing Drain hose joiner Phillips 5 8 16 mm screws 9 Drain hose support 1 Moisture protection tape 1 to prevent moisture damage to cabinetry Drain hose joiner 1 Top mounting brackets 2 OPTIONAL Prefinished toekick 1 Edge Protector 1 If the services hole is through a metal partition the hole must be protected with the Edge Protector supplied to prevent damage to the power cord...

Page 4: ...lide the terminal block cover sideways to unlock and hinge open to access the terminal block 6 Unscrew the Live Neutral and Earth wires as shown 7 Unscrew the three screws on the base as shown and remove the cord from the product 1 1 2 3 4 5 6 7 7 1 2 4 4 3 3 4 100 mm To prevent kinked hoses Either sit the drawer down on the left hand side recommended or rotate the drawer clockwise resting it on i...

Page 5: ...ed through or under under housing ribs 9 Screw down the Live Neutral and Earth wires correctly 10 Push the plastic harness cover back over It should clip back into place 11 Fold down and slide back the terminal block cover 12 Refit the electronics module back into position being careful of wiring 13 Replace the screw securing the electronics module 14 Slide the access cover back ensuring the 2 cli...

Page 6: ...ont panel 15 1 2 393 17 3 16 437 I Height of lower drawer front panel 14 356 12 1 4 312 J Height from top of drawer front panel to top of chassis 5 16 8 5 16 8 K Ventilation gap between drawer front panels 1 4 7 1 4 7 L Height of toekick customisable 2 13 16 5 72 127 2 13 16 5 72 127 M Depth from front of drawer panel to front of toekick adjustable 3 1 1 2 4 38 102 1 1 2 4 38 102 N Height of level...

Page 7: ...OFILE PLAN DD24DA DD24DCT CABINETRY DIMENSIONS INCHES MM INCHES MM P Inside height of cavity min 32 5 16 820 min 34 864 Q Inside width of cavity 23 5 8 600 23 5 8 600 R Inside depth of cavity min 22 1 16 560 min 22 1 16 560 S Recommended height of adjacent cabinet space 30 762 30 762 T Height of toekick space 2 3 8 4 3 4 60 120 3 15 16 6 5 16 100 160 depending on adjustment of leveling feet ...

Page 8: ...120 VAC max 15 A ø max 1 1 2 38 mm max 17 11 16 450 mm min 7 7 8 200 mm Moisture protection tape must be applied Services hole Can be located either side of dishwasher preferably at the bottom of the cavity as shown If adequate clearance services hole can be made higher to clear toekick space If hole is higher ensure drain hose s are routed straight into the waste connection If the hole is through...

Page 9: ... SIDE 7 MAXIMUM DISTANCE OF HOSES CORD FROM CHASSIS EDGE Drain hoses 78 1 2 2000 mm Drain hoses 70 1 2 1800 mm Inlet hose 64 3 4 1650 mm Inlet hose 49 1250 mm Power cord excl plug 29 1 2 750 mm Power cord excl plug 27 1 2 700 mm ...

Page 10: ...uct A A A B B Clip all four side mounting brackets into their slots using a flat bladed screwdriver Ensure they re securely fitted before sliding product into cavity The mounting slots are in pairs one on each side diagonally across the product A bracket must match A slot and B bracket must match B slot B A B You can raise or lower the product by twisting the feet Then take care when pushing the p...

Page 11: ...mseal x2 The top mounting brackets will only bend upwards a maximum of 3 8 10 mm 3 A FIT THE SUPPLIED TOEKICK PANEL 19 1 3 5 7 8 9 2 6 4 19 IMPORTANT Do not overtighten screw Where the toekick meets the bottom of the tub is the cut off point Mark this point on the toekick with a pencil Lay the toekick face down on a chopping board or similiar Smooth the edge with a file Be careful of sharp edges S...

Page 12: ... you do not bend the feet 9 B PULL THROUGH HOSES PUSH INTO THE CAVITY 0 B REMOVE THE LOWER DRAWER 4 100 mm 1 2 4 4 3 3 To prevent kinked hoses Either sit the drawer down on the left hand side recommended or rotate the drawer clockwise resting it on its side after removal Press the release tabs in on either side and push back to release drawer from runners Lift drawer off runners Push drawer runner...

Page 13: ... hand Ensure product is level and aligning with cabinetry Hexagonal socket x2 3 B REFIT THE DRAWER ONTO THE RUNNERS The top mounting brackets will only bend upwards a maximum of 3 8 10 mm 4 100 mm Pull the release tabs forward on both sides 4 100 mm Ensure the tabs are fully pulled forward and click into place Before refitting the drawer ensure the hoses are not twisted and the latches at the rear...

Page 14: ...a pencil Lay the toekick face down on a chopping board or similiar Smooth the edges with a file Be careful of sharp edges Snap off the two end tabs Slide the toekick onto the mounting rails either side and screw the toekick onto the bottom of tub on either side Mounting rail Score along the marked cutoff line with a knife Turn the toekick over and score along the same line Gently snap off the exce...

Page 15: ...MPORTANT Ensure that drain connection will comply with local plumbing regulations min R 8 200 mm 29 1 2 34 3 4 750 882 5 mm 1 1 2 po 38 mm 29 1 2 34 3 4 750 883 mm Screw Drain hose support to back wall at correct height If space is limited for fixing push hose through drain hose support to required height max 4 3 4 po 120 mm step 16 min 19 11 16 500 mm ...

Page 16: ...ual Double Air Gap Break Kit This provides totally separate draining for each drawer and eliminates possible cross draining problems DRAINAGE OPTION 2 Dishwasher using Dual Air Gap Break with Drain Hose Joiner 37 3 8 950 mm Max height to top of Air Break countertop or wall mounted 1 2 step 16 Drain hose Drain hose Secure both drain hoses to a Dual Air Gap Break ...

Page 17: ...883 mm step 16 Supplied drain hose joiner to suit Ø 3 4 19 mm waste tee Ensure drain hose is routed straight to joiner Remove excess drain hose material if necessary Do not shorten the inlet hose 29 1 2 34 3 4 750 882 5 mm Screw Drain hose support to back wall at correct height If space is limited for fixing push hose through drain hose support to required height max 4 3 4 po 120 mm min 19 11 16 5...

Page 18: ... Preference options section of the Quick start guide An option called Open drawer auto power on may need to be turned on Water around water supply and drainage connections Check connections existing plumbing and hoses for leaks Check rubber washer and hose clamp are correctly fitted If product is tipping Ensure the product is secured to the cabinetry If front panels are misaligned Check and releve...

Page 19: ...higher than the drain hose joiner Ensure any packaging or tape securing the racks is removed from the drawers Water softener models only adjust the water softener setting from the default setting to suit the water hardness of the area See the Quick start guide and section Water softener in the User guide Turn on the power and water supplies then open the drawers You should hear a beep and see a pr...

Page 20: ......

Reviews: