Fisher & Paykel DD24DCHTX6V2 Installation Instructions Manual Download Page 3

2” x 4”

PARTS SUPPLIED

Clamp (1)

Wire clip (2)

Phillips 

16 mm 

screws (9)

Drain hose 

support (1)

Moisture protection 

tape (1)

(to prevent moisture 

damage) 

Drain hose 

joiner (1)

Top 

mounting 

brackets (2)

Side mounting

bracket kit

(A and B)

 (2)

OPTIONAL

Prefinished toekick (1)

white or black

Washer (1)

Edge protector (1)

(if services hole 

partition is metal)

If the Drain hose(s) supplied are not long enough to reach your services, you 

must

 use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose(s) by 11’ 10” (3.6 m). The kit is available from the nearest 

Fisher & Paykel Authorized Service Agent, or Toll free 1.888.936.7872 or www.fisherpaykel.com. 

Hexagonal

socket (2)

(long & short)

 Important! 

Be sure the edges of the services hole are smooth or covered. If the services 
hole is through a metal partition the hole must be protected with the Edge 
protector supplied to prevent damage to the power cord or hoses.

 

These marks indicate mounting bracket screw locations

 

Preferred position. If adequate clearance, services hole can be 
higher to clear toekick space.

 

If hole is higher, ensure drain hose(s) are routed straight into the 
waste connection.

 

Water Connection

 

Recommended 

HOT

 (Maximum 140°F/60°C).

 

Supplied hose to suit 3/8” (9 mm) male compression fitting.

*

110-120 VAC
max. 15 A

Note: S

ervices can be locat

ed 

either side of DishDra

wer®.

max. ø 

½

  

(38 mm)

*

*

min. 

7⁄8

” 

(200 mm)

3⁄8” 

(10 mm)

max. 

17 

11⁄16

” 

(450 mm)

If no side partition, use a 

brace for securing.

CAVITY PREPARATION

4

5

 

Water Pressure  

 

Max

 

 

 

Min

 

Water softener models 

 

1 MPa (145 psi) 

 

0.1 MPa (14.5 psi)

 

Other models   

 

1 MPa (145 psi) 

 

0.03 MPa (4.3 psi)

 

Drains will need to be separated to satisfy kosher requirements. We suggest you confirm 
acceptability with your local rabbi in respect to kosher installations.

Left hand 

side

Right hand 

side

Water supply

Moisture 

protection 

tape must 

be applied.

Max. distance of 
hoses and cord from 
chassis edge 

Left hand 

side

Right hand 

side

Drain hose

78 ½

  ”

 

(2000 mm)

70 ½

  ”

 

(1800 mm)

Inlet hose

64 ¾

  ”

 

(1650 mm)

49”

 

(1250 mm)

Power cord 

(excl. plug)

29 ½

  ”

 

(750 mm)

27 ½

  ”

 

(700 mm)

(2,1)  -1- 599632C DD24D TALL installA2 USCA.indd 15/4/09 11:50:45 AM

(2,1)  -1- 599632C DD24D TALL installA2 USCA.indd 15/4/09 11:50:45 AM

Summary of Contents for DD24DCHTX6V2

Page 1: ...ilar mobile facility you must bring the vehicle boat or mobile facility containing the product to the service shop at your expense or pay the service technician s travel to the location of the product...

Page 2: ...lots on top of chassis 1 16 2 1 16 2 1 16 2 N height of drawer fronts 29 9 16 751 30 1 16 764 30 762 min Chassis heights include bracket slots less the Toekick Panel thickness Minimum Panel thickness...

Page 3: ...learance services hole can be higher to clear toekick space If hole is higher ensure drain hose s are routed straight into the waste connection Water Connection Recommended HOT Maximum 140 F 60 C Supp...

Page 4: ...d Ensure the drawer clips on both sides are reset Ensure the drawer is now rotated clockwise back Remove knock out for cable clamp Fit suitable cable clamp for the conduit and terminate the wiring as...

Page 5: ...1 2 ROUTE THE HOSES 7 OR Tie together to avoid kinking 1 1 2 599632C DD24D TALL installA2 USCA indd 15 4 09 11 51 16 AM 1 1 2 599632C DD24D TALL installA2 USCA indd 15 4 09 11 51 16 AM...

Page 6: ...into the cavity that you do not bend the feet Ensure the drawer is removed and then rotated counter clockwise to prevent kinked hoses 5 7 8 150 mm MOVE INTO THE CAVITY REMOVE THE DRAWER ATTACH SIDE M...

Page 7: ...HE TOEKICK 10 10 11 Before refitting the drawer ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward Ensure the drawer clips on both sides are reset En...

Page 8: ...to top of Air Break countertop or wall mounted Fit supplied washer Ensure hoses are routed straight to joiner Remove excess hose material if necessary DishDrawer and Standpipe 1 1 2 38 mm 29 34 750 88...

Page 9: ...r each drawer Spray arm Excessive water remaining above the filter plate after the rinse cycle Check for kinked drain hoses or blocked waste connection high loop not properly installed or drain hoses...

Reviews: