Fisher & Paykel DCS SBE1 Series Installation Manual Download Page 4

3

SAVE THESE INSTRUCTIONS

The models shown in this installation guide may not be available in all markets and are subject to 

change at any time. For current details about model and specification availability in your country, 

please visit our website dcsappliances.com or contact your local DCS dealer.

z

z

Do not store a full LP tank in direct sunlight.

z

z

After a period of storage or non-use, the appliance should be checked for gas leaks, 

deterioration, proper assembly, and burner obstructions before use.

General Use

z

z

This appliance is not intended to be installed in or on recreational vehicles, trailers or 

boats. 

z

z

After lighting burners, ensure they are operating correctly.

z

z

When using the appliance, be sure that all parts of the unit are firmly in place and that 

everything is stable.

z

z

On cart mounted units, never move without first allowing the appliance to cool, 

disconnecting the cable and ensuring that the gas supply is turned off.

z

z

Do not move the appliance during use.

z

z

Children should not be left alone or unattended in an area where the product is being 

used. Never allow them to sit, stand or play on or around the unit at any time.

z

z

Do not store items of interest to children around or below the appliance.

z

z

Never use the appliance in a windy area.

z

z

To put out flare-ups, adjust the controls to lower the temperature.

z

z

Do not obstruct the flow of combustion and ventilation to the appliance.

z

z

Spiders and insects can nest in the burners or openings and can block or restrict the 

burner. This can cause a flash back to the control panel which can cause a fire.

z

z

Do not try lighting this appliance without reading the lighting instruction in the user guide.

z

z

Do not locate, store or operate the appliance on a slope.

z

z

This product must be installed by a licensed plumber or gas fitter when installed within 

the Commonwealth of Massachusetts.

z

z

Never use a dented or rusty LP tank. Keep the ventilation openings of the cylinder 

enclosure free and clear from debris.

z

z

Clean and perform general maintenance on the appliance regularly. Watch for corrosion, 

cracks, or insect activity. Check the regulator, hoses, burner ports, air shutter, and venturi/

valve section carefully. Always turn off gas at the source prior to inspecting.

z

z

You must inspect the unit at least once a year or immediately if the smell of gas is present 

in conjunction with the burner flames appearing yellow, the appliance does not reach 

temperature or heats unevenly or the unit makes popping noises.

z

z

Do not smoke while leak testing and extinguish all open flames.

z

z

When cleaning the burners centre the burner onto the orifice correctly and ensure they 

are level before lighting to prevent fire hazard or explosion. Refer to the user guide for 

detailed guidance. 

z

z

Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas 

appliance.

z

z

Unplug from the outlet when not in use and before cleaning. Allow to cool before putting 

on or taking off parts.

z

z

Do not operate the appliance with a damaged cord, plug, or after the appliance 

malfunctions or has been damaged in any manner. Contact the manufacturer for repair.

z

z

Do not let the cord hang over the edge of a table or touch hot surfaces.

z

z

When connecting, first connect plug to the appliance then plug appliance into the outlet.

z

z

Do not place the unit directly on the ground or other surface without support. This will 

prevent damage to the regulator/hose assembly.

Gas requirements

z

z

This appliance can be used with any brand of 20lb LP gas tank provided it is compatible 

with a proper retention device (not supplied).

z

z

The LP gas cylinder must be:

z

z

Designed for use with a Type 1 system only.

z

z

Constructed and marked in accordance with the Specifications for LP gas Cylinders of 

the U.S. Department of Transportation (D.O.T.) or the Standard for Cylinders, Spheres 

and Tubes for Transportation of Dangerous Goods and Commission, CAN/CSA-B339

z

z

Provided with a listed overfilling prevention device.

z

z

Provided with a cylinder connection device compatible with the connection for outdoor 

cooking gas appliances

z

z

The cylinder must be provided with a shut-off valve terminating in an LP gas supply 

cylinder valve outlet specified, as applicable, for connection Type 1.

z

z

Do not change the regulator/hose assembly from that supplied with the unit or attempt 

to use a Type 1 equipped regulator/hose assembly with a standard 510 POL tank/valve 

assembly.

z

z

Never use a cylinder with a damaged valve. The cylinder that is used must have a collar to 

protect the cylinder valve.

z

z

An installer-supplied gas shut-off valve must be installed in an easily accessible location

z

z

All installer supplied parts must conform to local codes, or in the absence of local codes, 

with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA 

C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CSA-B149.1 Natural Gas Installation 

Code or CSA-B149.2 Propane Installation Code.

z

z

In Massachusetts such shut-off valves should be approved by the Board of State Examiners 

or Plumbers & Gas Fitters.

z

z

All pipe sealants must be an ap proved type and resistant to the actions of LP gases. Never 

use pipe sealant on flare fittings.

z

z

A dented or rusty LP tank may be hazardous and should be checked by your LP supplier.

z

z

Always check for leaks after every LP tank change.

z

z

Gas leak testing must be carried out by a qualified technician.

z

z

For LP units, check with a full cylinder.

z

z

Do not use the appliance until all connections have been checked and do not leak.

z

z

Before each use, inspect the gas supply piping or hose prior to turning the gas ON. If 

there is evidence of cuts, wear, or abrasion, it must be replaced prior to use. The pressure 

regulator and hose assembly supplied with the unit must be used. If replacements are 

needed, contact customer care at www.dcsappliances.com

SAFETY AND WARNINGS

Summary of Contents for DCS SBE1 Series

Page 1: ...SBE1 Models DOUBLE SIDE BURNER INSTALLATION GUIDE US CA 592072A 11 19...

Page 2: ...ever remove the grounding plug or use with a 2 prong adapter Use only extension cords with a 3 prong grounding plug rated for the power of the equipment and approved for outdoor use with a W A marking...

Page 3: ...fuel supply hose away from any heated surfaces WARNING To reduce the risk of fire injury to persons or damage when using the appliance follow the important safety instructions listed below Read all th...

Page 4: ...cooking gas appliance z z Unplug from the outlet when not in use and before cleaning Allow to cool before putting on or taking off parts z z Do not operate the appliance with a damaged cord plug or af...

Page 5: ...Overall depth excluding dials 26 7 8 683 D Depth of chassis 22 9 16 573 E Width of chassis including support brackets 11 7 8 301 F Height below countertop 9 15 16 253 G Height of surface above counter...

Page 6: ...es to prevent gas build up in the event of a leak Refer to ANSI Z21 58 Standard for Outdoor Cooking Gas Appliances Section 1 7 Enclosures For Self Contained LP Gas Supply Systems The side burner can b...

Page 7: ...power transformer to operate the products ignition and dial illumination features The transformer is sealed in a box with an attached power supply cord ELECTRICAL CONNECTION TO OUTLET Dial halos When...

Page 8: ...n the appliance rating plate agrees with that of the supply The rating plate is located on the underside of the drip tray Never connect an unregulated gas line to the appliance You must use a gas regu...

Page 9: ...en an LP unit is being directly connected to an LP house system you must follow the natural gas connection guidelines The installer must provide the proper gas regulator to reduce the gas pressure to...

Page 10: ...and one part water Pour into a spray bottle Ensure all control valves are in the OFF position before turning the gas supply ON Check all connections from the supply line or LP cylinder by applying the...

Page 11: ...with adjacent burner lit the pressure regulator is connected and set for 4 0 W C Natural 11 0 W C LP gas the manual shut off valve is installed and accessible the unit has been tested and is free of...

Page 12: ...nt apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should therefore check wi...

Reviews: