12
LEAK TESTING
1
2
Prepare soap solution by combining
one part liquid detergent and one
part water. Pour into a spray bottle.
Ensure all control valves are in the
OFF
position before turning the gas
supply
ON
.
Check all connections from the
supply line or LP cylinder by
applying the solution around the
connection, tubing and end of the
manifold. Soap bubbles will appear
where a leak is present.
A complete gas tightness check must be performed at the installation site. Periodically
check the whole system for leaks, or immediately if the smell of gas is present.
When using a LP gas cylinder ensure it is installed in a vertical position to provide the
required vapor withdrawal.
If a leak is present
Immediately turn the gas supply
OFF
and tighten any leaking connections. Turn gas
ON
,
and recheck. If you cannot stop a gas leak turn the gas supply
OFF
and call your local gas
utility or the dealer you purchased the appliance from. Only parts recommended by the
manufacturer should be used on the unit, substitution can void the warranty.
leak points
leak points
NG:
leak points
LP:
Changing the LP cylinder
Ensure the main tank valve is turned off before turning the coupler counter clockwise, the
inlet will then disengage. Remove the inlet from the tank valve opening. Your local LP filling
station should be equipped with the proper equipment to fill your tank.
Do not attempt to remove, repair or replace the regulator/hose assembly. This must be
done by qualified and licensed technician only.