
10
LEAK TESTING
RADIANT TRAYS
Unlock radiant end cap by pushing it up with two fingers and replace broken ceramic rod.
Lock radiant end cap. To order replacement rods, please visit www.dcsappliances.com
If a ceramic rod breaks
2
1
3
4
Unlock radiant end cap by
pushing it up with two fingers.
Unpack ceramic rods and remove
radiant from the unit.
Place all ceramic rods
onto the radiant.
Lock radiant end cap and place the
assembled radiant into the unit.
Before assembling the radiant, check that the radiant trays have not moved during transit.
They should sit securely on their locating pins in the base of the grill.
1
2
Prepare soap solution by combining
one part liquid detergent and one
part water. Pour into a spray bottle.
Ensure all control valves are in the
OFF
position before turning the gas
supply
ON
.
Check all connections from the
supply line or LP cylinder by
applying the solution around the
connection, tubing and end of the
manifold. Soap bubbles will appear
where a leak is present.
A complete gas tightness check must be performed at the installation site. Periodically check
the whole system for leaks, or immediately if the smell of gas is present.
If a leak is present
Immediately turn the gas supply
OFF
and tighten any leaking connections. Turn gas
ON
,
and recheck. If you cannot stop a gas leak turn the gas supply
OFF
and call your local gas
utility or the dealer you purchased the appliance from. Only parts recommended by the
manufacturer should be used on the grill, substitution can void the warranty.
leak points
leak points
NG:
leak points
LP: