B. If flow / fountain has stopped (check power supply first!):

Remove pump (15) and completely dissemble to the component parts as shown in

Fig. D as follows:
i) Disconnect all items attached to outlet adapter (16) and remove top cover (1)

by releasing the retaining clips at both ends, as shown by arrows (A) and (B) in

Fig. C.

ii) Remove pump (15) by holding the rear of the motor and carefully lifting out from

the UV outlet chamber (10) as shown by arrows (A) and (B) in Fig. E.

iii) Remove impeller cover (34) by rotating anticlockwise.
iv) Carefully pull out pump impeller assembly (37) and (38).
v) After cleaning all components:

• Check for wear of impeller (37) on shaft (38) and condition of rubber bushes

(36). Replace with new pump if required.

• Check cable and pump body (15) for any damage or deterioration and discard

pump if suspected faulty.

vi) Carefully reassemble all parts in reverse sequence.

C. Annual maintenance

In addition to the routine maintenance (section 3A) we recommend:

UV chamber and quartz tube

The UV chamber (5) and quartz tube (8) should only be cleaned if dirty.
i) Disconnect all items attached to outlet adapter (16) and remove top cover (1)

by releasing the retaining clips at both ends, as shown by arrows (A) and (B) in

Fig. C.

ii) Remove filter foams (2) and (3) and lift off UV chamber cover (4).
iii) Flex  side  wall  of  base  unit  (20)  as  shown  by  arrow  (S)  in  Fig. A  and  lift  out

complete  UV  chamber  assembly  (5,  10  and  13)  carefully  pulling  UV  outlet

chamber (10) away from pump (15).

iv) Release retaining clip (9) and remove UV outlet chamber (10) by turning UV inlet

chamber  (5)  firmly  in  direction  of  arrow  (T,  Fig.  A)  while  holding  UV  outlet

chamber (10) to reveal quartz tube (8).

v) Clean  out  UV  inlet  chamber  (5).  Carefully  clean  quartz  tube  (8)  using  a

non-scratch scouring pad.

vi) Re-fit UV inlet chamber (5) to UV outlet chamber (10) ensuring that inlet / outlet

are aligned.

vii) Carefully reassemble taking care to clip the complete UV assembly (5, 10 and

13) into base unit (20).

UV lamp replacement

The  UV  output  of  the  lamp  (12)  reduces  over  time  and  after  12  months  running

should be replaced. Note that the UV lamp will carry on giving off violet light well after

the UV light that kills the algae has stopped. We recommend the lamp is replaced at

the start of summer so that it is at its most efficient when the need is greatest.

• For  safety  the  filter  is  fitted  with  a  low  voltage  UV  lamp,  ensure  that  the

replacement lamp type is 12V / 11W.

i) Disconnect all items attached to outlet adapter (16) and remove top cover (1) by

releasing the retaining clips at both ends, as shown by arrows (A) and (B) in

Fig. C.

ii) Remove filter foams (2) and (3) and lift off UV chamber cover (4).
iii) Flex  side  wall  of  base  unit  (20)  as  shown  by  arrow  (S)  in  Fig. A  and  lift  out

complete  UV  chamber  assembly  (5,  10  and  13)  carefully  pulling  UV  outlet

chamber (10) away from pump (15).

iv) Remove UV lamp holder (13) from UV outlet chamber (10) by turning as shown

by arrow (R) in Fig. A.

v) Remove UV lamp (12) by pulling away from UV lamp holder (13). Pull the UV

lamp (12) straight out in the direction shown by arrow (P) in Fig. A.

vi) Confirm  that  your  new  FISH  MATE  UV  lamp  voltage/wattage  is  correct  by

checking  that  the  voltage/wattage  on  the  UV  lamp  (12)  is  the  same  as  the

old part.

vii) Fit new UV lamp (12) by pushing into UV lamp holder (13).
viii) Re-fit UV lamp holder (13) onto UV outlet chamber (10) ensuring UV chamber

O-ring (11) is in place in groove at end of UV outlet chamber (10).

ix) Carefully reassemble taking care to clip the complete UV assembly (5, 10 and

13) into base unit (20).

4. TROUBLE SHOOTING
A. Water does not clear

• The water should start to clear in 2 to 3 weeks, but full clarification may take 1 to 2

months. If the pond water is very green a partial water change should be made

before starting the filter. Thereafter the filter will keep the water clear. 

• If the UV lamp (12) is over 12 months old replace with new FISH MATE UV lamp.
• Check UV lamp is working (see section 4B). Never look at the UV lamp (12) directly

as it produces UV-C light which may be harmful to the eyes and skin.

• Check that you have selected the correct size filter for your pond (see carton).
• Check that the filter is being run 24 hours a day throughout the year except when

there is a risk of the water freezing.

• Set flow control (22) to maximum flow and use a plume fountain.
• Check quartz tube (8) is not dirty. Clean carefully if necessary.
• Do not feed your fish more food daily than they can consume in 2-3 minutes. We

recommend the use of our FISH MATE automatic fish feeders - specially designed

for safe feeding of fish.

• Do not use a lawn or pond plant fertiliser.

B. Testing the lamp
WARNING:  UV  lamps  emit  radiation  that  can  be  harmful  to  eyes  and  skin.

When checking the UV lamp you should never look directly at the light. Only

view using the lamp indicator lens (6).

• Test that the UV lamp is functioning as follows:
i) Disconnect electrical supply to filter and remove from pond.
ii) Disconnect  all  items  attached  to  outlet  adapter  (16)  remove  top  cover  (1)  by

releasing the retaining clips at both ends, as shown by arrows (A) and (B) in

Fig. C.

iii) Remove filter foams (2) and (3) and lift off UV chamber cover (4). 

DO NOT lift

out UV chamber assembly (5, 10 and 13) or remove foams (17) and (18).

iv) Connect the UV transformer (14) 

ONLY

to power supply.

v) Confirm that the UV lamp is working by looking at the lamp indicator lens (6).

NOTE: Only a small amount of safe light will be coming through the lamp indicator
lens (6) so you may have to cup your hands over the indicator.

C. Blanket weed

• This filter will not eliminate blanket weed.
• Increased use of plants in the pond may be beneficial.
• Do not use lawn or pond plant fertiliser.

D. The flow coming out of the filter has reduced over time

• The flow will naturally reduce as the filter gets dirty.
• Perform routine maintenance (see section 3A).