1. PUMP INSTALLATION

Ideally  and  for  convenience  the  pump  should  be

positioned  within  reach  of  the  side  of  the  pond  on  a

solid platform (e.g. paving slabs). The pump must be

at  least  8”  (200mm)  below  water  level  to  avoid

problems  of  freezing  and  low  water  levels  in

summer (Fig. 4).

Only use pump if completely immersed in water.

A. Waterfall/Filter Only

For use with a pond filter you will often get improved

results with the pump sited at the opposite end of the

pond to the filter return.
The  pump  comes  as  standard  with  pond-life  friendly

1

/

8

” (3mm) slots to help protect spawning life. In some

ponds this may not be necessary and you may want

to  modify  the  pump  to  enable  solids-handling  as

below.
The  pump  may  be  connected  to  a  waterfall  or  filter

using 

3

/

4

”  (19mm),  1”  (25mm)  or  1

1

/

4

”  (32mm)  bore

hose.  For  maximum  flow  use  1

1

/

4

”  (32mm)  hose

connected directly to the hose adaptor (Z), nut (P) and

pump outlet (C).
If a horizontal outlet is required or flow rate needs to be

controlled fit flow valve (K) with hose adaptor (Z) and

nut (P) into pump outlet (C). Fit blanking plug (N) to

vertical  fountain  outlet  (M)  and  adjust  flow  using  the

flow control knob (L).

•  Solids-handling

-  Remove  strainer  cover  (A)  by

squeezing  sides  and  pulling  off  as  shown  by  the

three arrows in Fig. 1. With a sharp knife cut alternate

ribs on bottom of cover (A) as shown in Fig. 2.
Reassemble and position pump at the bottom of the

pond.

B. Fountain (and Waterfall/Filter)

Insert  fountain  components  as  shown  in  Fig.  3a

(conventional fountain) / 3b (bell fountain). If required

tube (T) may be shortened with a hacksaw. For plume

fountain  do  not  fit  any  parts  to  tube  (T).  If  using

waterfall/filter, connect waterfall/filter to horizontal hose

adaptor (Z). Adjust fountain height/width using the flow

control  (L)  turning  clockwise  for  increased  height.

If using the bell fountain you will also need to manually

adjust  the  gap  between  parts  (X)  and  (W)  for  the

required  effect.  (Try  starting  with  approximately

1

/

16

”  (1mm)  gap.)  The  Fountain  heads  may  be

unscrewed anticlockwise for cleaning.

2. MAINTENANCE/TROUBLESHOOTING (see Fig. 1).

IMPORTANT SAFETY INSTRUCTIONS

• Disconnect  electrical  supply  from  pump

before  removing  from  pond  or  contacting

pond water.

• Do not carry or pull the pump by the cable.

A. When flow from your pump is noticeably reduced

or fountain display has deteriorated:

i) Remove strainer cover (A) by squeezing sides and

pulling off as shown by the three arrows in Fig.1.

Clean cover (A) and remove any weed or blockage

around pump inlet (B).

ii) If  you  are  using  a  fountain,  remove  and  clean

fountain head in water with a brush.

iii) Reassemble.  If  flow  is  still  poor  check  to  see  if

outlet pipe has become kinked or blocked.

B. If flow is stopped (check power supply first!):

i) Disconnect power.
ii) Remove  cover  (A)  and  check  for  free  rotation/

breakage of impeller (F).

iii) If impeller will not turn or is broken, pull off handle

(I)  as  shown  in  Fig.  1.  Undo  4  screws  (G)  and

remove  pump  body  (D).  Finally  pull  out  impeller

assembly  (E)  and  replace  if  broken  or  worn.  If  in

doubt  contact  Pet  Mate  Customer  Service.

Reassemble in reverse order after careful cleaning

of all components.

iv) Replace  the  pump  in  water  before  reconnecting

power to start pump. If pump does not start or stops

again please contact Pet Mate Customer Service.

1

IMPORTANT - READ BEFORE USE

Pet Mate Ltd. guarantees your product for a period of 3 years

from the date of purchase, subject to the registration of your

purchase details on our website 

www.pet-mate.com/us

within

14 days of purchase. (If you do not have access to a computer,

please send details of your purchase with copy of receipt along

with your name and address.) In the event of a fault developing

contact Pet Mate customer services for a returns authorisation

number. The guarantee is limited to any defect arising due to

faulty  materials  or  manufacture.  Any  defective  item  will  be

repaired  or  replaced  free  of  charge  at  the  manufacturer’s

discretion,  provided  that  the  defect  has  not  been  caused  by

neglect,  misuse  or  normal  wear  and  tear.  The  guarantee

excludes moving parts and claims arising from frost, accidental

damage or loss of fish. Your statutory rights are not affected.

A

C

N

M

L

K

B

D

E

F

G

I

P

Z

O

IMPORTANT SAFETY

INSTRUCTIONS

WARNING - To guard

against injury or death,

basic safety precautions

should be observed,

including the following:

READ AND FOLLOW

ALL SAFETY

INSTRUCTIONS

• Register  your  purchase  on-line

at 

www.pet-mate.com/us

(see

guarantee below).

• All electrical work must be carried

out by a competent electrician.

• Check that the voltage label on the

motor (H) see Fig. 1 conforms with

your supply voltage.

• The  pump  MUST  be  wired  into  a

ground  fault  circuit  interrupter

(G.F.C.I.)  maximum  30mA  and  a

3 AMP (maximum) fuse.

• Connection  to  the  power  supply

should be made through a double

pole  switched  enclosure  with

minimum 

1

/

8

”  (3mm)  contact

separation in all poles.

• This appliance must be earthed. It

is essential that all connections are

securely made using the following

code:

Black - Live
White - Common
Green - Ground

• Do not carry or pull the pump using

the supply cord.

• Disconnect  electrical  supply  from

all appliances in the pond including

pumps  and  filters  before  contact

with the pond water or pump.

• Maximum  operation  depth  is  5ft

(1.5m).

• Closely  supervise  children  when

near to pond or pond equipment.

• Use pump only for ponds - do not

use  pump  in  connection  with

swimming pools, showers, etc.

• Use  conduit  approved  by  your

electricity  authority  to  protect

supply  cord  where  damage  from

gardening equipment, children and

animals may occur.

• Discard  pump  if  motor  (H)  shows

visual  defects  (e.g.  cracks  or

swelling).

• The supply cord of this appliance

cannot be replaced; if the cord is

damaged the appliance should be

discarded.

• Do not allow the pump to run dry.
• Do  not  operate  the  pump  in

freezing  conditions.  Remove,

disassemble and dry pump if there

is a risk of pump being frozen.

• This  pump  is  provided  with  a

thermal  cut-out  switch  that

temporarily switches off the pump

in case of overheating. The pump

may restart when it has cooled.

SAVE THESE

INSTRUCTIONS

FISH MATE 1500 / 1900 / 2300

®

Pond Pump

· Instructions

www.pet-mate.com

(936) 760 4333

H