![FISCHER EU05 Operating Manual Download Page 11](http://html1.mh-extra.com/html/fischer/eu05/eu05_operating-manual_2294190011.webp)
FISCHER Mess- und Regeltechnik GmbH
Technical data | 5
BA_EN_EU05_ST4-A
11 / 16
5 Technical data
5.1 Auxiliary energy
The following data refers to the power supply via a power supply unit. However,
power can be supplied via an USB interface.
Rated Voltage
24 V AC/DC
Admissible operating voltage U
b
12 … 30 V AC/DC
Power consumption
≤ 4 W
Electrical plug
M12 flanged connector 5-pin coded
Optional NiMH battery
2200 mAh
Runtime in battery mode
(+)
approx. 4 hours.
(+)
The runtime depends on the connected transmitter type.
5.2 Application conditions
Ambient temperature range
0 … +40 °C
Storage temperature range
-10 … +50 °C
Max. humidity
80% rel. hum.
Protection class IP
IP20
Supported operating systems
Windows XP 32 Bit
Windows Vista 32 Bit
Windows 7 32/64 Bit
EMC Directive
2004/108/EC
DIN EN 61000-6-2
Correction 1:2011-06
EMC Part 6-2: Generic standards -
Immunity for industrial environments
DIN EN 61000-6-3
Correction 1:2012-11
EMC Part 6-3: Generic standards -
Emissions for residential, commercial
and light industry
RoHS Directive
2011/65/EU
DIN EN 50581:2013-02
Technical documentation for assess-
ment of electronic and electrical units
with respect to limitation of dangerous
substances
5.3 Interfaces
PC interface
USB 2.0
Electrical plug
USB bush type B
Transmitter connection
Electrical plug
M12 coupling