FISCHER EU05 Operating Manual Download Page 11

FISCHER Mess- und Regeltechnik GmbH

Technical data | 5

BA_EN_EU05_ST4-A

11 / 16

5 Technical data

5.1 Auxiliary energy

The following data refers to the power supply via a power supply unit. However,
power can be supplied via an USB interface.

Rated Voltage

24 V AC/DC

Admissible operating voltage U

b

12 … 30 V AC/DC

Power consumption

≤ 4 W

Electrical plug

M12 flanged connector 5-pin coded

Optional NiMH battery

2200 mAh

Runtime in battery mode 

(+)

approx. 4 hours.

(+)

 The runtime depends on the connected transmitter type.

5.2 Application conditions

Ambient temperature range

0 … +40 °C

Storage temperature range

-10 … +50 °C

Max. humidity

80% rel. hum.

Protection class IP

IP20

Supported operating systems

Windows XP 32 Bit
Windows Vista 32 Bit
Windows 7 32/64 Bit

EMC Directive

2004/108/EC

DIN EN 61000-6-2 
Correction 1:2011-06

EMC Part 6-2: Generic standards - 
Immunity for industrial environments

DIN EN 61000-6-3 
Correction 1:2012-11

EMC Part 6-3: Generic standards -
Emissions for residential, commercial
and light industry

RoHS Directive

2011/65/EU

DIN EN 50581:2013-02

Technical documentation for assess-
ment of electronic and electrical units
with respect to limitation of dangerous
substances

5.3 Interfaces

PC interface

USB 2.0

Electrical plug

USB bush type B

Transmitter connection

Electrical plug

M12 coupling

Summary of Contents for EU05

Page 1: ...Operating manual EU05 Transmitter PC Interface 09005821 BA_EN_EU05 ST4 A 11 15 09005821...

Page 2: ...sing electronic sys tems or any other form print photocopy microfilm or another process without the written consent of the company Fischer Mess und Regeltechnik GmbH Bad Salzuflen Reproduction for int...

Page 3: ...ractices for maintenance and installation work 5 1 8 Pictogram explanation 5 2 Product and functional description 6 2 1 Delivery scope 6 2 2 Product overview 6 2 3 Use as intended 7 3 Commissioning 8...

Page 4: ...the pertinent standards 1 3 Risks due to Non Observance of Safety Instructions Non observance of these safety instructions the intended use of the device or the limit values given in the technical sp...

Page 5: ...ation DANGER Type and source of danger This indicates a direct dangerous situation that could lead to death or serious injury highest danger level a Avoid danger by observing the valid safety regulati...

Page 6: ...ope Transmitter PC Interface EU05 Programming cable USB cable Plug power supply unit CD ROM with PC software FernPara TransPara Transmitter Programmer Operating Instructions 2 2 Product overview Power...

Page 7: ...39 Digital differential pressure transmitter DE44 Digital two channel differential pressure switch transmitter DE45 Digital differential pressure switch transmitter DE46 Digital differential pressure...

Page 8: ...s supplied to the connected transmitter via the EU05 and only when connected to an USB interface The remote configuration of the connected transmitter is realised with a special PC software depending...

Page 9: ...use 7 for the software required for your transmitter type All software is on the supplied CD You can download the latest software for free from our web site www fischermesstechnik de For information...

Page 10: ...able transport container 4 3 Service All defective or faulty devices should be sent directly to our repair department Please coordinate all shipments with our sales department Return the device in the...

Page 11: ...erature range 0 40 C Storage temperature range 10 50 C Max humidity 80 rel hum Protection class IP IP20 Supported operating systems Windows XP 32 Bit Windows Vista 32 Bit Windows 7 32 64 Bit EMC Direc...

Page 12: ...4 A 5 4 Construction design Installation position User defined Dimensions W x L x H 101 x 195 x 44 mm Weight approx 450g Materials Housing ABS 5 4 1 Dimensional drawings All dimensions in mm unless ot...

Page 13: ...0 5 Type Battery 0 0 1 2 3 4 Code no 4 code 0 Without battery 1 With battery 6 1 Accessories Order no Description 06405132 Plug power supply unit 06411148 Programming cable coupling connector 5 pin M1...

Page 14: ...nments EG 61000 6 3 2006 A1 2010 German ver sion EN 61000 6 3 2007 A1 2011 Gorrigendum to DIN EN 61000 6 3 VDE 0839 6 3 2011 09 German version EN 61000 6 3 2007 A1 2011 AG 2012 RoHS Technical document...

Page 15: ...FISCHER Mess und Regeltechnik GmbH Attachments 7 BA_EN_EU05_ST4 A 15 16...

Page 16: ...7 Attachments FISCHER Mess und Regeltechnik GmbH 16 16 BA_EN_EU05_ST4 A...