11  Technical data 

 

 

General points 

 

Admissible ambient temperature 

-

10 … +70 °C 

 

Admissible media temperature 

-

10 … +70 °C 

 

Admissible storage temperature 

-

15 … +75 °C 

 

Enclosure protection class 

IP55 acc. to DIN EN 60529 

 

Weight 

1.2 kg (Pressure chamber in aluminium) 
3.5 kg (Pressure chamber in stainless steel 1.4305) 

 

 

Measuring system 

 

Measuring range ≤ 16 bar  Pressure spring measuring diaphragm system made of fabric-reinforced elastomers 

 

Measuring range 0 … 25 bar  Plate spring measuring system, plate spring made of DURATHERM

©

 

 

Measuring range 

0 … 400 mbar to 0 … 25 bar (see order code) 

 

 Rated pressure of the 

measuring system 

25 bar 

 

Max. static operating pressure 

depending on measuring range (see order code) 

 

Max. pressure load 

 

on-sided over-pressure-proof up to the rated pressure of the measuring system 
resistance to under-pressure on the (+) and (-) side 

 

Measurement accuracy 

± 2.5% of the upper range value 

 

Zero-point adjustment 

Arranged in the front panel of the scale 

 

 

Switch contacts 

 

Contact output 

1 or 2 micro-switches with 1-pin changeover contact. 

 

Switch point setting 

 

can be set to reference scales from outside 
Smallest settable value approx. 5% of the end value of the measuring range. 

 

Switch hysteresis 

approx. 2.5% of the upper range value 

 

Load data/contact 

AC 

DC 

 

 

U

max

 

250V  

30V  

 

 

I

max

 

5A 

0.4A 

 

 

P

max

 

250 VA 

10 W 

 

 

 

Ports 

 

Process connection 

Inner thread G 1/4 
Connecting shank G¼ DIN EN 837 
Cutting ring connections for 6, 8, 10 mm (brass, steel galvanized or stainless steel) 

 

electr. connection 

 
 

Fixed wire numbered cables 
Cable connection socket 
7-pole plug connection 

 

 

Materials 

 

Pressure chamber 

Aluminium GkAlSi10(Mg), painted black 

 

 

Aluminium GkAlSi10(Mg) with HART-COAT©-surface protection 

 

 

Chromium nickel steel 1.4305 

 

Measuring diaphragm 

Measuring diaphragm and seals made of NBR or Viton©

 

 

 

Plate spring made of DURATHERM© NiCrCo alloy

 

 

Inner parts in contact with 

mediums 

Stainless steel 1.4310, 1.4305 

 

Hood 

Makrolon 

 

 

Mounting 

 

Installation position 

vertical 

 

 

Wall mounting - three mounting feet 
Control panel assembly - control panel installation set DZ11 Ø132mm 
Pipe connection, pressure connections acc. to attached symbols 
-  via screwed-in cutting or clamp screw connections 
-  via screwed-in connection shanks acc. to DIN EN 837  
  for nipple connections acc. to DIN 16284 

 

 

Approvals 

 

 

type testing according to the regulations of Det Norske Veritas and the Germanischen Lloyd, 
test symbol DNV-GL 

 

 

EAC Declaration of conformity 

 

 

EN 61508 2001 Functional safety of safety-related electrical/electronic/ 
programmable electronic systems requirements for SIL2 

 

 

 

Summary of Contents for DS 11

Page 1: ...ar with the in stallation commissioning and operation of this product Specialized personnel are persons who can assess the work they have been assigned and recognize potential dangers by virtue of their specialized train ing their skills and experience and their knowledge of the pertinent standards 1 3 Risks due to Non Observance of Safe ty Instructions Non observance of these safety instructions ...

Page 2: ...toring filters and pumps Pressure chamber and measuring diaphragms are available in various materials This allows the devices to be adapted to the various requirements 3 Product and functional description 3 1 Function diagram Item Description 1 Pressure chamber 2 Motion train 3 Tappet 4 Micro switch 5 Switch point setting 6 Measuring diaphragm 7 Measuring springs 3 2 Design and mode of operation A...

Page 3: ...r pressure to the side of the device When measuring the pressure only the connection is used the connection is used to measure under pressure The pressure sensing lines need to be kept as short as possible and installed without sharp bends to avoid interfering delay times The pressure sensing lines must be installed on a gradient so that no air pockets e g for liquid meas urements or water pockets...

Page 4: ... Set the measurement value pointer to the zero point scale using the zero point correction screw Re mount the hood 5 3 Switch point setting Remove the plug in the hood The required switch points can be set guide value scales according to the markings by us ing a screwdriver The achievable setting accu racy is 5 1 Replace the plug after completing the settings 5 4 Function test Remove both plugs in...

Page 5: ...tected against impacts It should be transported in the original packaging or a suitable transport container 8 Service All defective or faulty devices should be sent direct ly to our repair department Please coordinate all shipments with our sales department Warning Process media residues in and on dismantled devices can be a hazard to people animals and the environment Take adequate preventive mea...

Page 6: ...measuring range Switch hysteresis approx 2 5 of the upper range value Load data contact AC DC Umax 250V 30V Imax 5A 0 4A Pmax 250 VA 10 W Ports Process connection Inner thread G 1 4 Connecting shank G DIN EN 837 Cutting ring connections for 6 8 10 mm brass steel galvanized or stainless steel electr connection Fixed wire numbered cables Cable connection socket 7 pole plug connection Materials Press...

Page 7: ... Process connection variants M20x1 5 Cable screw connection Cable connection socket or 7 pin plug connection SW19 Connection G inner thread Connection spigot G according to DIN EN 837 DZ 13 14 Four spindle equalization and shut off valve Mounting the control panel opened opened Measuring device Venting Function diagram DZ 13 14 Venting n a for DZ13 Cutting ring screw connection Control panel cut o...

Page 8: ...read 1 4 18 NPT EXT Chrome Nickel Steel 1 4 Cutting ring screw connection made of steel for 6 mm pipe 2 0 Cutting ring screw connection made of steel for 8 mm pipe 2 1 Cutting ring screw connection made of steel for 10 mm pipe 2 2 Cutting ring screw connection made of 1 4571 for 6 mm pipe 2 4 Cutting ring screw connection made of 1 4571 for 8 mm pipe 2 5 Cutting ring screw connection made of 1 457...

Page 9: ...d or taken out of operation for repairs or tests to disconnect differential pressure devices within the affected systems from the mains supply The shutoff devices can therefore also be used for function tests on site In contrast to DZ13 the DZ14 also has a venting valve to vent the conected pipe system The shutoff and venting valves are designed for the rated pressure level PN40 The housing can be...

Page 10: ...10 16 Page 14 Manufacturer s Declarations and Certificates 14 1 EC Declaration of conformity ...

Page 11: ...11 16 Page 14 2 Certificate functional security SIL2 ...

Page 12: ...12 16 Page ...

Page 13: ...13 16 Page 14 3 GL approval ...

Page 14: ...14 16 Page ...

Page 15: ...15 16 Page ...

Page 16: ...ithout notice Changements techniques sous réserve Fischer Mess und Regeltechnik GmbH Bielefelder Str 37a D 32107 Bad Salzuflen Tel 49 5222 9740 Fax 49 5222 7170 eMail info fischermesstechnik de www fischermesstechnik de 14 4 EAC Declaration of conformity ...

Reviews: