6.4.2 Electrical connection
In the case of devices with additional electronic equipment, the connection is
realised using a cable socket attached to the side and/or with a Han 7D con-
nector on th epower plant models. The pin assignment depends on the ordered
mode and is stated in the data sheet KE or KE09.
Cable socket
HAN 7D
Fig. 22:
Cable socket
Cable socket
Number of screw terminals
6 + 2PE
Rated current
See data sheet KE
Rated voltage
250V
Cable diameter
up to 1.5 mm
2
with wire protection
Cable screw connection
M20 x 1.5, terminal range 7 … 13 mm
HAN 7D
No. of crimp contacts
7 + PE
Rated current
See data sheet KE
Rated voltage
50V
Cable diameter
1 mm
2
Cable screw connection
M20 x 1.5, terminal range 7 … 13 mm