![Fischer Panda Panda 25i PMS User Manual Download Page 90](http://html1.mh-extra.com/html/fischer-panda/panda-25i-pms/panda-25i-pms_user-manual_2294283090.webp)
Installation Instructions
Seite/Page 90 - Kaptitel/Chapter 5: Installation Instructions
20.7.15
All electrical safety installations have to be made on board.
Required cable cross-sections
The following recommended electrical cable dimensions (cross sections) are the minimum required sizes for a safe
installation. (see section 9.2, “Technical data,” on page 149)
Fig. 5.11.0-1: Electrical installation - example
Fig. 5.11.0-2: Electrical installation parallel OPERATION- example
5.11.1 Installation PMGi inverter - See separate PMGi 15000 inverter manual
1
2
3
4
5
6
7
1. Generator
2. Electrical fuel pump 12VDC
3. PMGi 15000 inverter
4. iControl panel
5. Starter battery DC
6. Fuse
7. Battery switch