Maintenance Instructions
9.12.14
Kapitel/Chapter 9: Maintenance Instructions - Seite/Page 119
Fig. 9.10.1.2-2: Demounting the bearing cap
Demounting the bearing cover
• Unscrew fixing bolts (Tools Allen key SW6).
• Fasten fixing bolts by hand into the holes for disengaging
as far as possible.
• Then alternately fasten these three bolts equaly.
Thus the bearing cover will be pushed out of the
generator cap equally.
• Remove ball bearing with a usual extractor from the shaft.
01. Bearing cover
02. Fixing screw
03. Holes for disengaging
Sample picture
Note:
If there is no suitable extractor available, a suitable
extractor can be purchased from Fischer Panda.
Check the O-ring seal which is mounted in the bearing
cover and replaced if damaged.
9.10.1.3 Installing the new backend bearing
Fig. 9.10.1.3-1: 1Mount bearing cover
Mount bearing case in the generator cap.
Place bearing case loosely into the generator cap,
assure with one hand against falling out.
Thereby pay attention that the case is mounted in the
same position as before - the previously added markings
have to match again!
Sample Picture
02
01
02
02
03
03